O. Reg. 503/09: BUILDING CODE

filed December 21, 2009 under Building Code Act, 1992, S.O. 1992, c. 23

Skip to content

 

ontario regulation 503/09

made under the

building code act, 1992

Made: December 16, 2009
Filed: December 21, 2009
Published on e-Laws: December 22, 2009
Printed in The Ontario Gazette: January 9, 2010

Amending O. Reg. 350/06

(Building Code)

1. (1) Subclause 1.1.2.2.(1)(b)(iv) of Division A of Ontario Regulation 350/06 is amended by striking out “medium and low hazard industrial occupancies” at the end and substituting “medium hazard industrial occupancies and low hazard industrial occupancies”.

(2) Sentence 1.1.2.2.(2) of Division A of the Regulation is amended by striking out “and” at the end of Clause (b) and by revoking Clause (c) and substituting the following:

(c) a retaining wall exceeding 1 000 mm in exposed height adjacent to,

(i) public property,

(ii) access to a building, or

(iii) private property to which the public is admitted,

(d) a pedestrian bridge appurtenant to a building,

(e) a crane runway,

(f) an exterior storage tank and its supporting structure that is not regulated by the Technical Standards and Safety Act, 2000,

(g) signs regulated by Section 3.15. of Division B that are not structurally supported by a building,

(h) a structure that supports a wind turbine generator having a rated output of more than 3 kW, 

(i) a communication tower exceeding 16.6 m above ground level, and

(j) an outdoor pool that has a water depth greater than 3.5 m at any point.

2. Subclause 1.1.2.4.(1)(c)(iv) of Division A of the Regulation is amended by striking out “medium hazard industrial occupancies and low hazard industrial occupancies” at the end and substituting “medium hazard industrial occupancies and low hazard industrial occupancies”.

3. Sentence 1.1.2.7.(1) of Division A of the Regulation is amended by striking out “Section 9.40.” and substituting “Section 9.41.”.

4. Clause 1.1.3.1.(1)(a) of Division A of the Regulation is amended by striking out “Section 2.2.” and substituting “Section 1.2.”.

5. Clauses 1.3.1.1.(1)(j) to (l) of Division A of the Regulation are revoked and the following substituted:

(j) an outdoor pool, and

(k) Reserved

(l) an outdoor public spa.

6. (1) Sentence 1.3.1.2.(1) of Division A of the Regulation is amended by striking out “Sentences (2) to (5)” and substituting “Sentences (2) to (4)”.

(2) Sentence 1.3.1.2.(5) of Division A of the Regulation is revoked and the following substituted:

(5) A liquid manure storage tank shall comply with the requirements of Part 4 of Division B of this Code and the requirements of Part 4 of the CCBFC, “National Farm Building Code of Canada”.

7. (1) The definition of “basement” in Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by striking out “first storey” at the end and substituting “first storey”.

(2) The definition of “Building Code website” in Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by striking out “www.obc.mah.gov.on.ca” at the end and substituting “www.ontario.ca/buildingcode”.

(3) Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by adding the following definition:

Certificate for the occupancy of a building described in Sentence 1.3.3.4.(4) of Division C means a certificate described in Sentence 3.7.4.3.(5.1) of Division C.

(4) The definition of “Certificate for the occupancy of a building not fully completed” in Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by striking out “Sentence 4.7.4.3.(5)” and substituting “Sentence 3.7.4.3.(5)”.

(5) The definition of “Circuit vent” in Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by striking out “them”.

(6) Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by adding the following definition:

Individual vent means a vent pipe that serves one fixture.

(7) Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by adding the following definition:

Liquid manure means manure having a dry matter content of less than 18 per cent or a slump of more than 150 millimetres using the Test Method for the Determination of Liquid Waste (slump test) set out in Schedule 9 to Regulation 347 of the Revised Regulations of Ontario, 1990 (General — Waste Management) made under the Environmental Protection Act.

(8) Clause 1.4.1.2.(1)(b) of Division A of the Regulation is amended by adding the following definition:

Tarion Warranty Corporation means Tarion Warranty Corporation as designated under section 2 of the Ontario New Home Warranties Plan Act.

8. Sentence 1.4.1.3.(1) of Division A of the Regulation is amended by adding the following clause:

(c.1) by-laws made under section 108 of the City of Toronto Act, 2006, but only with respect to the issuance of a permit for the construction of a green roof if the construction of the roof is prohibited unless a permit is obtained,

9. (1) Item 8 of Table 1.4.2.1. of Division A of the Regulation is amended by striking out “decibel-weighted sound level” in Column 3 and substituting “A-weighted sound level”.

(2) Table 1.4.2.1. of Division A of the Regulation is amended by adding the following item:

 

36.1

min.

minimum

(3) Item 51 of Table 1.4.2.1. of Division A of the Regulation is amended by striking out “cross-linked polyethylene” in Column 3 and substituting “crosslinked polyethylene”.

10. The title to Division B of the Regulation is revoked and the following substituted:

DIVISION b
acceptable solutions

11. Sentence 1.3.1.1.(1) of Division B of the Regulation is amended by striking out “May 31, 2006” at the end and substituting “November 30, 2009”.

12. Table 1.3.1.2. of Division B of the Regulation is revoked and the following substituted:

Table 1.3.1.2.
Documents Referenced in the Building Code

Forming Part of Sentence 1.3.1.2.(1)

 

Column 1

Column 2

Column 3

Column 4

Issuing Agency

Document Number

Title of Document

Code Reference

ACGIH

2007, 26th Edition

Industrial Ventilation Manual

6.2.1.1.(1)

ANSI

A208.1-1999

Particleboard, Mat-Formed Wood

Table 5.10.1.1.

 

 

 

9.23.14.2.(3)

 

 

 

9.29.9.1.(1)

 

 

 

9.30.2.2.(1)

ANSI/ASHRAE

62.1-2004

Ventilation for Acceptable Indoor Air Quality

6.2.2.1.(2)

 

 

 

6.2.3.8.(15)

ANSI/ASHRAE/IESNA

90.1-2004

Energy Standard for Buildings Except Low-Rise Residential Buildings

6.2.1.1.(1)

 

 

 

12.2.1.1.(2)

ANSI/ASME

A112.19.8-2007

Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Whirlpool Bathtub Appliances

3.12.4.1.(9)

ANSI/ASME

B16.3-2006

Malleable Iron Threaded Fittings, Classes 150 and 300

7.2.6.6.(1)

ANSI/ASME

B16.4-2006

Gray Iron Threaded Fittings, Classes 150 and 250

7.2.6.5.(1)

 

 

 

Table 7.2.11.2.

ANSI/ASME

B16.12-1998

Cast Iron Threaded Drainage Fittings

7.2.6.3.(1)

ANSI/ASME

B16.15-2006

Cast Bronze Threaded Fittings, Classes 125 and 250

7.2.7.3.(1)

ANSI/ASME

B16.18-2001

Cast Copper Alloy Solder Joint Pressure Fittings

7.2.7.6.(1)

 

 

 

7.2.7.6.(2)

 

 

 

Table 7.2.11.2.

ANSI/ASME

B16.22-2001

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

7.2.7.6.(1)

ANSI/ASME

B16.23-2002

Cast Copper Alloy Solder Joint Drainage Fittings: DWV

7.2.7.5.(1)

ANSI/ASME

B16.24-2001

Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 400, 600, 900, 1500 and 2500

7.2.7.2.(1)

ANSI/ASME

B16.26-2006

Cast Copper Alloy Fittings for Flared Copper Tubes

7.2.7.7.(1)

 

 

 

7.2.7.7.(2)

 

 

 

Table 7.2.11.2.

ANSI/ASME

B16.29-2001

Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings - DWV

7.2.7.5.(1)

ANSI/ASME

B18.6.1-1981

Wood Screws (Inch Series)

Table 5.10.1.1.

 

 

 

9.23.3.1.(2)

ANSI/AWWA

C104 / A21.4-2003

Cement-Mortar Lining for Ductile-Iron Pipe Fittings for Water

7.2.6.4.(2)

 

 

 

Table 7.2.11.2.

ANSI/AWWA

C110 / A21.10-2003

Ductile-Iron and Gray-Iron Fittings for Water

7.2.6.4.(3)

 

 

 

Table 7.2.11.2.

ANSI/AWWA

C111 / A21.11-2007

Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings

7.2.6.4.(4)

 

 

 

Table 7.2.11.2.

ANSI/AWWA

C151 / A21.51-2002

Ductile-Iron Pipe, Centrifugally Cast, for Water

7.2.6.4.(1)

 

 

 

Table 7.2.11.2.

ANSI/CSA

ANSI Z21.22-1999 / CSA 4.4-M99

Relief Valves for Hot Water Supply Systems

7.2.10.11.(1)

ANSI/CSA

ANSI Z21.22a-2000 / CSA 4.4a-2000

Addenda 1 to ANSI Z21.22-1999 / CSA 4.4-M99, Relief Valves for Hot Water Supply Systems

7.2.10.11.(1)

ANSI/CSA

ANSI Z21.22b-2001 / CSA 4.4b-2001

Addenda 2 to ANSI Z21.22-1999 / CSA 4.4-M99, Relief Valves for Hot Water Supply Systems

7.2.10.11.(1)

APHA/AWWA/WEF

2005, 21st Edition

Standard Methods for the Examination of Water and Waste Water

8.9.2.4.(1)(b)

ASHRAE

2009

Fundamentals

6.2.1.1.(1)

ASHRAE

2007

HVAC Applications

6.2.1.1.(1)

ASHRAE

2008

HVAC Systems and Equipment

6.2.1.1.(1)

ASHRAE

2006

Refrigeration

6.2.1.1.(1)

ASSE

1010-2004

Water Hammer Arresters

7.2.10.15.(1)

ASSE

1051-2002

Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems

7.2.10.16.(1)

ASTM

A53 / A53M-06a

Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless

7.2.6.7.(4)

ASTM

A123 / A123M-02

Zinc (Hot Dip Galvanized) Coatings on Iron and Steel Products

Table 5.10.1.1.

 

 

 

Table 9.20.16.1.

ASTM

A153 / A153M-05

Zinc Coating (Hot-Dip) on Iron and Steel Hardware

Table 5.10.1.1.

 

 

 

Table 9.20.16.1.

ASTM

A252-98

Welded and Seamless Steel Pipe Piles

4.2.3.8.(1)

ASTM

A283 / A283M-03

Low and Intermediate Tensile Strength Carbon Steel Plates

4.2.3.8.(1)

ASTM

A518 / A518M-99

Corrosion-Resistant High-Silicon Iron Castings

7.2.8.1.(1)

ASTM

A653 / A653M-06a

Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

Table 5.10.1.1.

 

 

 

9.3.3.2.(1)

ASTM

A792 / A792M-06a

Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process

9.3.3.2.(1)

ASTM

A1008 / A1008M-07

Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable

4.2.3.8.(1)

ASTM

A1011 / A1011M-06b

Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength

4.2.3.8.(1)

ASTM

B32-04

Solder Metal

7.2.9.2.(2)

ASTM

B42-02e1

Seamless Copper Pipe, Standard Sizes

7.2.7.1.(1)

ASTM

B43-98e1

Seamless Red Brass Pipe, Standard Sizes

7.2.7.1.(2)

ASTM

B68-02

Seamless Copper Tube, Bright Annealed

7.2.7.4.(3)

ASTM

B88-03

Seamless Copper Water Tube

7.2.7.4.(1)

 

 

 

Table 7.2.11.2.

ASTM

B306-02

Copper Drainage Tube (DWV)

7.2.7.4.(1)

ASTM

B813-00e1

Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy and Tube

7.2.9.2.(3)

ASTM

B828-02

Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

7.3.2.4.(1)

ASTM

C4-04e1

Clay Drain Tile and Perforated Clay Drain Tile

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

ASTM

C27-98

Classification for Fire Clay and High-Alumina Refractory Brick

9.21.3.4.(1)

ASTM

C126-99

Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

ASTM

C212-00

Structural Clay Facing Tile

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

ASTM

C260-06

Air-Entraining Admixtures for Concrete

9.3.1.8.(1)

ASTM

C411-05

Hot-Surface Performance of High-Temperature Thermal Insulation

6.2.3.4.(3)

 

 

 

6.2.9.2.(2)

ASTM

C412M-05a

Concrete Drain Tile (Metric)

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

ASTM

C444M-03

Perforated Concrete Pipe (Metric)

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

ASTM

C494 / C494M-05a

Chemical Admixtures for Concrete

9.3.1.8.(1)

ASTM

C700-07e1

Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

ASTM

C1002-04

Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs

Table 5.10.1.1.

 

 

 

9.24.1.4.(1)

 

 

 

9.29.5.7.(1)

ASTM

C1053-00

Borosilicate Glass Pipe and Fittings for Drain, Waste and Vent (DWV) Applications

7.2.8.1.(1)

ASTM

C1177 / C1177M-06

Glass Mat Gypsum Substrate for Use as Sheathing

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

ASTM

C1178 / C1178M-06

Coated Glass Mat Water-Resistant Gypsum Backing Panel

Table 5.10.1.1.

 

 

 

9.29.5.2.(1)

ASTM

C1396 / C1396M-06a

Gypsum Board

3.1.5.12.(4)

 

 

 

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

 

 

 

9.29.5.2.(1)

 

 

 

Table 9.29.5.3.

ASTM

D374-99

Thickness of Solid Electrical Insulation

3.15.4.1.(1)(c)

ASTM

D568-77

Rate of Burning and/or Extent and Time of Burning of Flexible Plastics in a Vertical Position

3.15.4.1.(1)(b)

ASTM

D635-06

Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position

3.15.4.1.(1)(a)

ASTM

D2178-04

Asphalt Glass Felt Used in Roofing and Waterproofing

Table 5.10.1.1.

ASTM

D2898-07

Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing

3.1.5.5.(4)

 

 

 

3.1.5.21.(1)

ASTM

D3261-03

Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing

7.2.5.5.(3)

ASTM

E90-04

Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

5.9.1.1.(1)

 

 

 

9.11.1.1.(1)

ASTM

E96 / E96M-05

Water Vapour Transmission of Materials

5.5.1.2.(3)

 

 

 

9.25.1.2.(1)

 

 

 

9.25.4.2.(1)

 

 

 

9.30.1.2.(1)

ASTM

E283-04

Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differentiation Across the Specimen

9.6.5.4.(1)

 

 

 

9.6.5.5.(1)

 

 

 

9.7.1.7.(1)

 

 

 

12.3.3.13.(1)

ASTM

E336-05

Measurement of Airborne Sound Attenuation Between Rooms  in Buildings

5.9.1.1.(1)

 

 

 

9.11.1.1.(1)

ASTM

E413-04

Classification for Rating Sound Insulation

5.9.1.1.(1)

 

 

 

9.11.1.1.(1)

ASTM

E2190-02

Insulating Glass Unit Performance and Evaluation

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

ASTM

F476-84

Security of Swinging Door Assemblies

9.6.8.10.(1)

ASTM

F628-06e1

Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe With a Cellular Core

7.2.5.10.(1)

 

 

 

7.2.5.12.(1)

 

 

 

7.2.5.12.(2)

ASTM

F714-06a

Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter

7.2.5.6.(1)

AWPA

M4-06

Care of Preservative-Treated Wood Products

4.2.3.2.(2)

 

 

 

Table 5.10.1.1.

BNQ

BNQ3624-115-2007

Polyethylene (PE) Pipe and Fittings - Flexible Pipes for Drainage - Characteristics and Test Methods

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

CCBFC

NRCC 38730

Model National Energy Code for Buildings 1997

6.2.2.1.(1)

 

 

 

12.2.1.1.(2)

 

 

 

12.2.1.2.(2)

CCBFC

NRCC 47666

National Building Code of Canada 2005

1.3.1.2.(3) of Division A

 

 

 

2.4.2.2.(1)(b)(iii) of Division C

CCBFC

NRCC 47668

National Plumbing Code of Canada 2005

2.4.2.2.(1)(b)(iii) of Division C

CCBFC

NRCC 47667

National Fire Code of Canada 2005

3.3.1.2.(1)

 

 

 

3.3.5.2.(1)

 

 

 

6.2.2.5.(1)

CCBFC

NRCC 38732

National Farm Building Code of Canada 1995

1.3.1.2.(1) to (5) of Division A

CGSB

CAN/CGSB-1.501-M89

Method of Permeance of Coated Wallboard

5.5.1.2.(2)

 

 

 

9.25.4.2.(6)

CGSB

CAN/CGSB-7.1-98

Lightweight Steel Wall Framing Components

9.24.1.2.(1)

CGSB

CAN/CGSB-7.2-94

Adjustable Steel Columns

9.17.3.4.(1)

CGSB

CAN/CGSB-10.3-92

Air Setting Refractory Mortar

9.21.3.4.(2)

 

 

 

9.21.3.9.(1)

 

 

 

9.22.2.2.(2)

CGSB

CAN/CGSB-11.3-M87

Hardboard

Table 5.10.1.1.

 

 

 

9.27.10.1.(2)

 

 

 

9.29.7.1.(1)

 

 

 

9.30.2.2.(1)

CGSB

CAN/CGSB-11.5-M87

Hardboard, Precoated, Factory Finished, for Exterior Cladding

Table 5.10.1.1.

 

 

 

9.27.10.1.(1)

CGSB

CAN/CGSB-12.1-M90

Tempered or Laminated Safety Glass

3.3.1.19.(2)

 

 

 

3.4.6.14.(1)

 

 

 

3.4.6.14.(3)

 

 

 

Table 5.10.1.1.

 

 

 

9.6.6.2.(2)

 

 

 

9.7.3.1.(1)

 

 

 

9.8.8.7.(1)

CGSB

CAN/CGSB-12.2-M91

Flat, Clear Sheet Glass

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

CGSB

CAN/CGSB-12.3-M91

Flat, Clear Float Glass

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

CGSB

CAN/CGSB-12.4-M91

Heat Absorbing Glass

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

CGSB

CAN/CGSB-12.5-M86

Mirrors, Silvered

9.6.6.3.(2)

CGSB

CAN/CGSB-12.8-97

Insulating Glass Units

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

CGSB

CAN/CGSB-12.10-M76

Glass, Light and Heat Reflecting

Table 5.10.1.1.

 

 

 

9.7.3.1.(1)

CGSB

CAN/CGSB-12.11-M90

Wired Safety Glass

3.3.1.19.(2)

 

 

 

3.4.6.14.(1)

 

 

 

3.4.6.14.(3)

 

 

 

Table 5.10.1.1.

 

 

 

9.6.6.2.(2)

 

 

 

9.7.3.1.(1)

 

 

 

9.8.8.7.(1)

CGSB

CAN/CGSB-12.20-M89

Structural Design of Glass for Buildings

4.3.6.1.(1)

 

 

 

9.7.3.2.(1)

CGSB

19-GP-5M-1984

Sealing Compound, One Component, Acrylic Base, Solvent Curing

Table 5.10.1.1.

 

 

 

9.27.4.2.(2)

CGSB

CAN/CGSB-19.13-M87

Sealing Compound, One Component, Elastomeric, Chemical Curing

Table 5.10.1.1.

 

 

 

9.27.4.2.(2)

CGSB

19-GP-14M-1984

Sealing Compound, One Component, Butyl-Polyisobutylene Polymer Base, Solvent Curing

Table 5.10.1.1.

 

 

 

9.27.4.2.(2)

CGSB

CAN/CGSB-19.22-M89

Mildew Resistant Sealing Compound for Tubs and Tile

9.29.10.5.(1)

CGSB

CAN/CGSB-19.24-M90

Multicomponent, Chemical-Curing Sealing Compound

Table 5.10.1.1.

 

 

 

9.27.4.2.(2)

CGSB

CAN/CGSB-34.4-M89

Siding, Asbestos-Cement, Shingles and Clapboards

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.5-M89

Sheets, Asbestos-Cement, Corrugated

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.9-M94

Asbestos-Cement Sewer Pipe

7.2.5.1.(2)

CGSB

CAN/CGSB-34.14-M89

Sheets, Asbestos-Cement, Decorative

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.16-M89

Sheets, Asbestos-Cement, Flat, Fully Compressed

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.17-M89

Sheets, Asbestos-Cement, Flat, Semicompressed

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.21-M89

Panels, Sandwich, Asbestos-Cement with Insulating Cores

Table 5.10.1.1.

 

 

 

9.27.8.1.(1)

CGSB

CAN/CGSB-34.22-94

Asbestos-Cement Drain Pipe

Table 5.10.1.1.

 

 

 

7.2.5.1.(1)

 

 

 

9.14.3.1.(1)

CGSB

CAN/CGSB-34.23-94

Asbestos-Cement House Connection Sewer Pipe

7.2.5.1.(2)

CGSB

CAN/CGSB-37.1-M89

Chemical Emulsified Type, Emulsified Asphalt for Dampproofing

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

CGSB

CAN/CGSB-37.2-M88

Emulsified Asphalt, Mineral Colloid Type, Unfilled, for Dampproofing and Waterproofing and for Roof Coatings

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

 

 

 

9.13.3.2.(1)

CGSB

CAN/CGSB-37.3-M89

Application of Emulsified Asphalts for Dampproofing or Waterproofing

5.8.2.3.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.13.2.3.(1)

 

 

 

9.13.3.3.(1)

CGSB

CAN/CGSB-37.4-M89

Fibrated, Cutback Asphalt, Lap Cement for Asphalt Roofing

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

CAN/CGSB-37.5-M89

Cutback Asphalt Plastic Cement

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

37-GP-6Ma-1983

Asphalt, Cutback, Unfilled, for Dampproofing

5.8.2.2.(6)

 

 

 

5.8.2.2.(7)

 

 

 

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

CGSB

CAN/CGSB-37.8-M88

Asphalt, Cutback, Filled, for Roof Coating

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

37-GP-9Ma-1983

Primer, Asphalt, Unfilled, for Asphalt Roofing, Dampproofing and Waterproofing

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

37-GP-12Ma-1984

Application of Unfilled Cutback Asphalt for Dampproofing

5.8.2.3.(2)

 

 

 

Table 5.10.1.1.

 

 

 

9.13.2.3.(1)

CGSB

CAN/CGSB-37.16-M89

Filled, Cutback Asphalt for Dampproofing and Waterproofing

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

 

 

 

9.13.3.2.(1)

CGSB

37-GP-18Ma-1985

Tar, Cutback, Unfilled, for Dampproofing

5.8.2.2.(6)

 

 

 

5.8.2.2.(7)

 

 

 

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

CGSB

37-GP-21M-1985

Tar, Cutback, Fibrated, For Roof Coating

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

CAN/CGSB-37.22-M89

Application of Unfilled, Cutback Tar Foundation Coating for Dampproofing

5.8.2.3.(2)

 

 

 

Table 5.10.1.1.

 

 

 

9.13.2.3.(1)

CGSB

37-GP-36M-1976

Application of Filled Cutback Asphalt for Dampproofing and Waterproofing

5.8.2.3.(1)

 

 

 

Table 5.10.1.1.

CGSB

37-GP-37M-1977

Application of Hot Asphalt for Dampproofing or Waterproofing

5.8.2.3.(1)

 

 

 

Table 5.10.1.1.

CGSB

CAN/CGSB-37.50-M89

Hot Applied, Rubberized Asphalt for Roofing and Waterproofing

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

CAN/CGSB-37.51-M90

Application for Hot Applied Rubberized Asphalt for Roofing and Waterproofing

5.6.1.3.(1)

 

 

 

5.8.2.3.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.26.15.1.(1)

CGSB

37-GP-52M-1984

Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

CAN/CGSB-37.54-95

Polyvinyl Chloride Roofing and Waterproofing Membrane

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

37-GP-55M-1979

Application of Sheet Applied Flexible Polyvinyl Chloride Roofing Membrane

5.6.1.3.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.26.16.1.(1)

CGSB

37-GP-56M-1985

Membrane, Modified, Bituminous, Prefabricated, and Reinforced for Roofing

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

37-GP-64M-1977

Mat Reinforcing, Fibrous Glass, for Membrane Waterproofing Systems and Built-up Roofing

Table 5.10.1.1.

CGSB

41-GP-6M-1983

Sheets, Thermosetting Polyester Plastics, Glass Fiber Reinforced

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CGSB

CAN/CGSB-41.24-95

Rigid Vinyl Siding, Soffits and Fascia

Table 5.10.1.1.

 

 

 

9.27.13.1.(1)

CGSB

CAN/CGSB-51.25-M87

Thermal Insulation, Phenolic, Faced

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

 

 

 

9.25.2.2.(1)

CGSB

51-GP-27M-1979

Thermal Insulation, Polystyrene, Loose Fill

Table 5.10.1.1.

 

 

 

9.25.2.2.(1)

CGSB

CAN/CGSB-51.32-M77

Sheathing, Membrane, Breather Type

Table 5.10.1.1.

 

 

 

9.20.13.9.(1)

 

 

 

9.26.2.1.(1)

 

 

 

9.27.3.2.(1)

CGSB

CAN/CGSB-51.33-M89

Vapour Barrier, Sheet, Excluding Polyethylene, for Use in Building Construction

Table 5.10.1.1.

 

 

 

9.25.4.2.(5)

CGSB

CAN/CGSB-51.34-M86 (amended 1988)

Vapour Barrier, Polyethylene Sheet for Use in Building Construction

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

 

 

 

9.13.4.2.(1)

 

 

 

9.18.6.2.(1)

 

 

 

9.25.3.2.(2)

 

 

 

9.25.4.2.(4)

CGSB

CAN/CGSB-63.14-M89

Plastic Skylights

5.10.1.1.(4)

 

 

 

Table 5.10.1.1.

 

 

 

9.7.7.1.(1)

 

 

 

9.7.7.2.(1)

CGSB

CAN/CGSB-82.1-M89

Sliding Doors

Table 5.10.1.1.

 

 

 

9.6.5.2.(1)

CGSB

CAN/CGSB-82.5-M88

Insulated Steel Doors

Table 5.10.1.1.

 

 

 

9.6.5.3.(1)

CGSB

CAN/CGSB-82.6-M86

Doors, Mirrored Glass, Sliding or Folding, Wardrobe

9.6.6.3.(1)

CGSB

CAN/CGSB-93.1-M85

Sheet, Aluminum Alloy, Prefinished Residential

Table 5.10.1.1.

 

 

 

9.27.12.1.(4)

CGSB

CAN/CGSB-93.2-M91

Prefinished Aluminum Siding, Soffits and Facsia for Residential Use

Table 5.10.1.1.

 

 

 

9.27.12.1.(3)

CGSB

CAN/CGSB-93.3-M91

Prefinished Galvanized and Aluminum-Zinc Alloy Steel Sheet for Residential Use

Table 5.10.1.1.

 

 

 

9.27.12.1.(2)

CGSB

CAN/CGSB-93.4-92

Galvanized Steel and Aluminum-Zinc Alloy Coated Steel Siding, Soffits and Fascia, Prefinished, Residential

Table 5.10.1.1.

 

 

 

9.27.12.1.(1)

CSA

CAN/CSA-6.19-01

Residential Carbon Monoxide Alarming Devices

6.2.12.3.(1)

 

 

 

9.33.4.3.(1)

CSA

CAN/CSA-A23.1-04

Concrete Materials and Methods of Concrete Construction

4.2.3.6.(1)

 

 

 

4.2.3.9.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.3.1.1.(4)

 

 

 

9.3.1.3.(1)

 

 

 

9.3.1.4.(1)

 

 

 

9.40.1.4.(1)

CSA

A23.3-04

Design of Concrete Structures

Table 4.1.8.9.

 

 

 

4.3.3.1.(1)

CSA

A60.1-M1976

Vitrified Clay Pipe

7.2.5.4.(1)

CSA

A60.3-M1976

Vitrified Clay Pipe Joints

7.2.5.4.(2)

CSA

CAN/CSA-A82.1-M87

Burned Clay Brick (Solid Masonry Units Made From Clay or Shale)

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A82.3-M1978

Calcium Silicate (Sand-Lime) Building Brick

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A82.4-M1978

Structural Clay Load-Bearing Wall Tile

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A82.5-M1978

Structural Clay Non-Load-Bearing Tile

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

CAN3-A82.8-M78

Hollow Clay Brick

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

CAN/CSA-A82.27-M91

Gypsum Board

3.1.5.12.(4)

 

 

 

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

 

 

 

9.29.5.2.(1)

CSA

A82.30-M1980

Interior Furring, Lathing and Gypsum Plastering

Table 5.10.1.1.

 

 

 

9.29.4.1.(1)

CSA

A82.31-M1980

Gypsum Board Application

Table 5.10.1.1.

 

 

 

9.10.12.4.(3)

 

 

 

9.29.5.1.(2)

CSA

CAN3-A93-M82

Natural Airflow Ventilators for Buildings

Table 5.10.1.1.

 

 

 

9.19.1.2.(5)

CSA

A123.1-05 /A123.5-05

Asphalt Shingles Made from Organic Felt and Surfaced with Mineral Granules / Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CSA

CAN/CSA-A123.2-03

Asphalt Coated Roofing Sheets

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CSA

A123.3-05

Asphalt Saturated Organic Roofing Felt

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CSA

CAN/CSA-A123.4-04

Asphalt for Constructing Built-Up Roof Coverings and Waterproofing Systems

Table 5.10.1.1.

 

 

 

9.13.2.2.(1)

 

 

 

9.13.3.2.(1)

 

 

 

9.26.2.1.(1)

CSA

A123.17-05

Asphalt Glass Felt Used in Roofing and Waterproofing

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CSA

CAN3-A123.51-M85

Asphalt Shingle Application on Roof Slopes 1:3 and Steeper

5.6.1.3.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.26.1.2.(1)

CSA

CAN3-A123.52-M85

Asphalt Shingle Application on Roof Slopes 1:6 to Less than 1:3

5.6.1.3.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.26.1.2.(1)

CSA

A165.1-04

Concrete Block Masonry Units

Table 5.10.1.1.

 

 

 

9.15.2.2.(1)

 

 

 

9.17.5.1.(1)

 

 

 

9.20.2.1.(1)

 

 

 

9.20.2.6.(1)

CSA

A165.2-04

Concrete Brick Masonry Units

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A165.3-04

Prefaced Concrete Masonry Units

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A165.4-M85

Autoclaved Cellular Units

Table 5.10.1.1.

 

 

 

9.20.2.1.(1)

CSA

A179-04

Mortar and Grout for Unit Masonry

Table 5.10.1.1.

 

 

 

9.15.2.2.(3)

 

 

 

9.20.3.1.(1)

CSA

CAN/CSA-A220.0-06

Performance of Concrete Roof Tiles

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

CSA

CAN/CSA-A220.1-06

Installation of Concrete Roof Tiles

Table 5.10.1.1.

 

 

 

9.26.17.1.(1)

CSA

A257 Series-03

Standards for Concrete Pipe and Manhole Sections

7.2.5.3.(1)

CSA

A257.4-03

Precast Reinforced Circular Concrete Manhole Sections, Catch Basins, and Fittings

7.2.5.3.(5)

CSA

A277-08

Procedure for Factory Certification of Buildings

9.1.1.9.(1)

CSA

CAN/CSA-A324-M88

Clay Flue Liners

9.21.3.3.(1)

CSA

A371-04

Masonry Construction for Buildings

5.6.1.3.(2)

 

 

 

Table 5.10.1.1.

 

 

 

9.15.2.2.(3)

 

 

 

9.20.3.2.(7)

 

 

 

9.20.15.2.(1)

CSA

CAN/CSA-A405-M87

Design and Construction of Masonry Chimneys and Fireplaces

9.21.3.5.(1)

 

 

 

9.22.1.4.(7)

 

 

 

9.22.5.2.(2)

CSA

CAN/CSA-A438-00

Concrete Construction for Housing and Small Buildings

9.3.1.1.(1)

CSA

CAN/CSA-A440-00

Windows

5.10.1.1.(3)

 

 

 

Table 5.10.1.1.

 

 

 

9.7.2.1.(1)

 

 

 

9.7.2.1.(2)

 

 

 

9.7.6.1.(1)

CSA

CAN/CSA-A440.1-00

User Selection Guide to CSA Standard CAN/CSA-A440-00, Windows

5.10.1.1.(3)

 

 

 

Table 5.10.1.1.

 

 

 

9.7.2.1.(1)

CSA

CAN/CSA-A440.2-M04

Energy Performance Evaluation of Windows and Sliding Glass Doors

12.3.1.3.(1)

CSA

A660-04

Certification of Manufacturers of Steel Building Systems

4.3.4.3.(1)

CSA

CAN/CSA-A3001-03

Cementitious Materials for Use in Concrete

Table 5.10.1.1.

 

 

 

9.3.1.2.(1)

 

 

 

9.28.2.1.(1)

CSA

ASME A17.1-2007 / CSA B44-07

Safety Code for Elevators and Escalators

3.5.2.2.(1)

 

 

 

Table 4.1.5.12.

 

 

 

7.4.3.6.(1)

CSA

CAN/CSA-B45.0-02

General Requirements for Plumbing Fixtures

7.6.4.2.(1)

CSA

CAN/CSA-B45.1-02

Ceramic Plumbing Fixtures

7.2.2.2.(2)

CSA

CAN/CSA-B45.2-02

Enamelled Cast Iron Plumbing Fixtures

7.2.2.2.(3)

CSA

CAN/CSA-B45.3-02

Porcelain-Enamelled Steel Plumbing Fixtures

7.2.2.2.(4)

CSA

CAN/CSA-B45.4-02

Stainless Steel Plumbing Fixtures

7.2.2.2.(5)

CSA

CAN/CSA-B45.5-02

Plastic Plumbing Fixtures

7.2.2.2.(6)

CSA

CAN/CSA-B45.9-02

Macerating Systems and Related Components

7.2.2.2.(8)

CSA

CAN/CSA-B45.10-01

Hydromassage Bathtubs

7.2.2.2.(7)

CSA

B52-05

Mechanical Refrigeration Code

6.2.2.4.(4)

CSA

CAN/CSA-B64.0-01

Definitions, General Requirements, and Test Methods for Vacuum Breakers and Backflow Preventers

7.2.10.10.(1)

CSA

CAN/CSA-B64.1.1-01

Vacuum Breakers, Atmospheric Type (AVB)

7.2.10.10.(1)

CSA

CAN/CSA-B64.1.2-01

Vacuum Breakers, Pressure Type (PVB)

7.2.10.10.(1)

CSA

CAN/CSA-B64.2-01

Vacuum Breakers, Hose Connection Type (HCVB)

7.2.10.10.(1)

CSA

CAN/CSA-B64.2.1-01

Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature

7.2.10.10.(1)

CSA

CAN/CSA-B64.2.2-01

Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature

7.2.10.10.(1)

CSA

CAN/CSA-B64.3-01

Backflow Preventers, Dual Check Valve Type Atmospheric

7.2.10.10.(1)

 

 

Port (DACP)

7.6.2.5.(4)

CSA

CAN/CSA-B64.4-01

Backflow Preventers, Reduced Pressure Principle Type (RP)

7.2.10.10.(1)

CSA

CAN/CSA-B64.4.1-01

Backflow Preventers, Reduced Pressure Principle Type for Fire Systems (RPF)

7.6.2.4.(2)

 

 

 

Table 7.6.2.4.

CSA

CAN/CSA-B64.5-01

Backflow Preventers, Double Check Valve Type (DCVA)

7.2.10.10.(1)

CSA

CAN/CSA-B64.5.1-01

Backflow Preventers, Double Check Valve Type for Fire Systems (DCVAF)

7.6.2.4.(2)

 

 

 

Table 7.6.2.4.

CSA

CAN/CSA-B64.6-01

Backflow Preventers, Dual Check Valve Type (DuC)

7.2.10.10.(1)

CSA

CAN/CSA-B64.6.1-01

Backflow Preventers, Dual Check Valve Type for Fire Systems (DuCF)

7.6.4.2.(2)

 

 

 

Table 7.6.2.4.

CSA

CAN/CSA-B64.7-01

Vacuum Breakers, Laboratory Faucet Type (LFVP)

7.2.10.10.(1)

CSA

CAN/CSA-B64.8-01

Backflow Preventers, Dual Check Valve Type with Intermediate Vent (DuCV)

7.2.10.10.(1)

CSA

CAN/CSA-B64.9-01

Backflow Preventers, Single Check Valve Type for Fire Systems (SCVAF)

7.6.2.4.(2)

 

 

 

Table 7.6.2.4.

CSA

CAN/CSA-B64.10-01

Manual for the Selection and Installation of Backflow Prevention Devices

7.2.10.10.(1)

CSA

B66-05

Design, Material, and Manufacturing Requirements for Prefabricated Septic Tanks and Sewage Holding Tanks

8.2.2.2.(1)

 

 

 

8.2.2.2.(2)

 

 

 

8.2.2.2.(3)

 

 

 

8.2.2.3.(7)

 

 

 

8.2.2.3.(11)

CSA

CAN/CSA-B70-06

Cast Iron Soil Pipe, Fittings and Means of Joining

7.2.6.1.(1)

 

 

 

7.4.6.4.(2)

CSA

B111-1974

Wire Nails, Spikes and Staples

9.23.3.1.(1)

 

 

 

9.26.2.2.(1)

 

 

 

9.29.5.6.(1)

CSA

ASME

Plumbing Supply Fittings

7.2.10.6.(1)

 

A112.18.1-2005 / CAN/CSA-B125.1-05

 

7.6.5.2.(1)

CSA

ASME

Plumbing Waste Fittings

7.2.3.3.(1)

 

A112.18.2-2005 / CAN/CSA-B125.2-05

 

7.2.10.6.(2)

CSA

CAN/CSA-B125.3-05

Plumbing Fittings

7.2.10.6.(1)

 

 

 

7.2.10.10.(2)

 

 

 

7.6.5.2.(2)

CSA

B127.1-99

Asbestos Cement Drain, Waste and Vent Pipe and Pipe Fittings

7.2.5.1.(1)

 

 

 

7.2.6.2.(1)

CSA

B127.2-M1977

Components for Use in Asbestos Cement Building Sewer Systems

7.2.5.1.(2)

 

 

 

7.2.6.2.(1)

CSA

CAN/CSA-B137.1-05

Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services

7.2.5.5.(1)

 

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.2-05

Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications

7.2.5.8.(1)

 

 

 

7.2.5.10.(1)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.3-05

Rigid Polyvinylchloride (PVC) Pipe for Pressure Applications

7.2.5.8.(1)

 

 

 

7.2.5.10.(1)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.5-05

Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications

7.2.5.7.(1)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.6-05

Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems

7.2.5.9.(1)

 

 

 

7.2.5.9.(2)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.9-05

Polyethylene/Aluminium/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems

7.2.5.13.(1)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.10-05

Crosslinked Polyethylene/Aluminum Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems

7.2.5.13.(4)

 

 

 

7.2.5.14.(1)

 

 

 

Table 7.2.11.2.

CSA

CAN/CSA-B137.11-05

Polypropylene (PP-R) Pipe and Fittings for Pressure Applications

7.2.5.15.(1)

CSA

B158.1-1976

Cast Brass Solder Joint Drainage, Waste and Vent Fittings

7.2.7.5.(1)

 

 

 

7.2.10.1.(1)

CSA

CAN/CSA-B181.1-06

Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings

7.2.5.10.(1)

 

 

 

7.2.5.11.(1)

 

 

 

7.2.5.12.(1)

 

 

 

7.2.5.12.(2)

 

 

 

7.2.10.1.(2)

 

 

 

7.4.6.4.(2)

CSA

CAN/CSA-B181.2-06

Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings

7.2.5.10.(1)

 

 

 

7.2.5.11.(1)

 

 

 

7.2.5.12.(1)

 

 

 

7.2.5.12.(2)

 

 

 

7.2.10.1.(3)

 

 

 

7.4.6.4.(2)

CSA

CAN/CSA-B181.3-06

Polyolefin and Polyvinylidene (PVDF) Laboratory Drainage Systems

7.2.8.1.(1)

CSA

CAN/CSA-B182.1-06

Plastic Drain and Sewer Pipe and Pipe Fittings

Table 5.10.1.1.

 

 

 

7.2.5.10.(1)

 

 

 

7.2.5.12.(2)

 

 

 

7.4.6.4.(2)

 

 

 

9.14.3.1.(1)

CSA

CAN/CSA-B182.2-06

PSM Type Polyvinylchloride (PVC) Sewer Pipe and Fittings

7.2.5.10.(1)

 

 

 

7.2.5.12.(2)

CSA

CAN/CSA-B182.4-06

Profile Polyvinylchloride (PVC) Sewer Pipe and Fittings

7.2.5.10.(1)

CSA

CAN/CSA-B182.6-06

Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-Proof Sewer Applications

7.2.5.10.(1)

CSA

CAN/CSA-B182.7-06

PSM Type Multilayer Polyvinylchloride (PVC) Sewer Pipe Having Reprocessed-Recycled Content

7.2.5.10.(1)

CSA

CAN/CSA-B214-07

Installation Code for Hydronic Heating Systems

6.2.1.4.(6)

CSA

B242-05

Groove and Shoulder-Type Mechanical Pipe Couplings

7.2.10.4.(1)

CSA

CAN/CSA-B272-93

Prefabricated Self-Sealing Vent Flashings

7.2.10.14.(2)

CSA

CAN/CSA-B355-00

Lifts for Persons with Physical Disabilities

3.8.3.5.(1)

CSA

CAN/CSA-B356-00

Water Pressure Reducing Valves for Domestic Water Supply Systems

7.2.10.12.(1)

CSA

CAN/CSA-B365-01

Installation Code for Solid-Fuel Burning Appliances and Equipment

6.2.1.4.(1)

 

 

 

9.21.1.3.(2)

 

 

 

9.22.10.2.(1)

 

 

 

9.33.1.2.(1)

CSA

CAN/CSA-B366.1-M91

Solid Fuel-Fired Central Heating Appliances

6.2.1.4.(2)

CSA

CAN/CSA-B602-05

Mechanical Couplings for Drain, Waste, and Vent Pipe and Sewer Pipe

7.2.5.3.(2)

 

 

 

7.2.10.4.(2)

CSA

CAN/CSA-C22.2

Test Methods for Electrical Wires and Cables

3.1.4.3.(1)

 

No. 0.3-01

 

3.1.4.3.(2)

 

 

 

3.1.5.18.(1)

 

 

 

3.1.5.18.(2)

 

 

 

3.1.5.21.(1)

 

 

 

3.1.5.21.(2)

 

 

 

3.6.4.3.(1)

CSA

C22.2 No.113-M1984

Fans and Ventilators

9.32.3.9.(6)

CSA

C22.2 No. 141-02

Unit Equipment for Emergency Lighting

3.2.7.4.(2)

 

 

 

9.9.11.3.(6)

CSA

C22.2 No. 211.0-03

General Requirements and Methods of Testing for Nonmetallic Conduit

3.1.5.20.(1)

CSA

CAN/CSA-C22.3 No. 1-2006

Overhead Systems

3.1.19.1.(2)

CSA

CAN/CSA-C88-M90

Power Transformers and Reactors

3.6.2.7.(10)

CSA

CAN/CSA-C260-M90

Rating for the Performance of Residential Mechanical Ventilating Equipment

9.32.3.9.(1)

 

 

 

9.32.3.9.(2)

 

 

 

Table 9.32.3.9.

CSA

CAN/CSA-C282-05

Emergency Electrical Power Supply for Buildings

3.2.7.5.(1)

CSA

CAN/CSA-C439-00

Rating the Performance of Heat/Energy-Recovery Ventilators

6.2.1.6.(2)

 

 

 

9.32.3.11.(2)

CSA

CAN/CSA-C448.1-02

Design and Installation of Earth Energy Systems for Commercial and Institutional Buildings

6.2.1.4.(4)

CSA

CAN/CSA-C448.2-02

Design and Installation of Earth Energy Systems for Residential and Other Small Buildings

6.2.1.4.(3)

CSA

CAN/CSA-F280-M90

Determining the Required Capacity of Residential Space Heating and Cooling Appliances

6.2.1.1.(1)

CSA

CAN/CSA-F326-M91

Residential Mechanical Ventilation Systems

6.2.1.1.(1)

CSA

F379.1-09

Packaged Solar Domestic Hot Water Systems (Liquid-to-Liquid Heat Transfer) for All-Season Use

7.2.10.13.(1)

 

 

 

7.6.2.5.(3)

 

 

 

7.6.2.5.(4)

CSA

F383-08

Installation of Packaged Solar Domestic Hot Water Systems

7.6.1.13.(1)

CSA

CAN/CSA-G30.18-M92

Billet Steel Bars for Concrete Reinforcement

9.3.1.1.(4)

 

 

 

9.40.1.3.(1)

CSA

CAN/CSA-G40.21-04

Structural Quality Steel

4.2.3.8.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.23.4.3.(2)

CSA

CAN/CSA-G164-M92

Hot Dip Galvanising of Irregularly Shaped Articles

4.4.4.1.(4)

CSA

G401-01

Corrugated Steel Pipe Products

7.2.6.8.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.14.3.1.(1)

CSA

O80 Series-97

Wood Preservation

3.1.4.4.(1)

 

 

 

4.2.3.2.(1)

 

 

 

4.2.3.2.(2)

 

 

 

Table 5.10.1.1.

CSA

O80.1-97

Preservative Treatment of All Timber Products by Pressure Processes

Table 5.10.1.1.

 

 

 

9.3.2.9.(5)

CSA

O80.2-97

Preservative Treatment of Lumber, Timber, Bridge Ties and Mine Ties by Pressure Processes

4.2.3.2.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.3.2.9.(5)

CSA

O80.3-97

Preservative Treatment of Piles by Pressure Processes

4.2.3.2.(1)

CSA

O80.9-97

Preservative Treatment of Plywood by Pressure Processes

Table 5.10.1.1.

 

 

 

9.3.2.9.(5)

CSA

O80.15-97

Preservative Treatment of Wood for Building Foundation Systems, Basements and Crawl Spaces by Pressure Processes

4.2.3.2.(1)

 

 

 

Table 5.10.1.1.

 

 

 

9.3.2.9.(5)

CSA

O80.34-97

Preservative Treatment of Lumber and Timbers with Borates for Use Out of Ground Contact and Continuously Protected from Liquid Water

Table 5.10.1.1.

 

 

 

9.3.2.9.(5)

 

 

 

9.3.2.9.(6)

CSA

O80.36-05

Preservative Treatment of Wood Products for Light-Duty Above-Ground Residential Uses by Pressure Processes

9.3.2.9.(5)

CSA

CAN/CSA-O86-01 (Including Supplement CAN/CSA-O86S1-05)

Engineering Design in Wood

Table 4.1.8.9.

 

 

 

4.3.1.1.(1)

CSA

O115-M1982

Hardwood and Decorative Plywood

Table 5.10.1.1.

 

 

 

9.27.9.1.(1)

 

 

 

9.30.2.2.(1)

CSA

O118.1-97

Western Cedars Shakes and Shingles

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

 

 

 

9.27.7.1.(1)

CSA

O118.2-M81

Eastern White Cedar Shingles

Table 5.10.1.1.

 

 

 

9.26.2.1.(1)

 

 

 

9.27.7.1.(1)

CSA

O121-M1978

Douglas Fir Plywood

Table 5.10.1.1.

 

 

 

9.23.14.2.(1)

 

 

 

9.23.15.2.(1)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.27.9.1.(1)

 

 

 

9.30.2.2.(1)

 

 

 

Table A-13

 

 

 

Table A-14

 

 

 

Table A-15

CSA

CAN/CSA-O122-06

Structural Glued-Laminated Timber

Table A-11

 

 

 

Table A-16

CSA

CAN/CSA-O132.2 Series-90

Wood Flush Doors

Table 5.10.1.1.

 

 

 

9.6.5.1.(1)

CSA

O141-05

Softwood Lumber

Table 5.10.1.1.

 

 

 

9.3.2.6.(1)

CSA

O151-04

Canadian Softwood Plywood

Table 5.10.1.1.

 

 

 

9.23.14.2.(1)

 

 

 

9.23.15.2.(1)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.27.9.1.(1)

 

 

 

9.30.2.2.(1)

 

 

 

Table A-13

 

 

 

Table A-14

 

 

 

Table A-15

CSA

O153-M1980

Poplar Plywood

Table 5.10.1.1.

 

 

 

9.23.14.2.(1)

 

 

 

9.23.15.2.(1)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.27.9.1.(1)

 

 

 

9.30.2.2.(1)

CSA

O177-06

Qualification Code for Manufacturers of Structural Glued-Laminated Timber

4.3.1.2.(1)

 

 

 

Table A-11

 

 

 

Table A-16

CSA

CAN/CSA-O325.0-92

Construction Sheathing

Table 5.10.1.1.

 

 

 

9.23.14.2.(1)

 

 

 

9.23.14.4.(2)

 

 

 

Table 9.23.14.5.B.

 

 

 

9.23.15.2.(1)

 

 

 

9.23.15.3.(2)

 

 

 

Table 9.23.15.7.B.

 

 

 

Table 9.23.16.2.B.

 

 

 

9.29.9.1.(2)

 

 

 

9.29.9.2.(5)

 

 

 

Table A-13

 

 

 

Table A-14

 

 

 

Table A-15

CSA

O437.0-93

OSB and Waferboard

Table 5.10.1.1.

 

 

 

9.23.14.2.(1)

 

 

 

9.23.14.4.(2)

 

 

 

9.23.15.2.(1)

 

 

 

9.23.15.3.(2)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.27.11.1.(1)

 

 

 

9.29.9.1.(2)

 

 

 

9.30.2.2.(1)

 

 

 

Table A-13

 

 

 

Table A-14

 

 

 

Table A-15

CSA

CAN/CSA-S16-01 CONSOLIDATION

Limit States Design of Steel Structures

Table 4.1.8.9.

 

 

 

4.3.4.1.(1)

CSA

S37-01

Antennas, Towers and Antenna Supporting Structures

4.1.1.4.(2)

CSA

CAN/CSA-S136-01 (Including Supplement CAN/CSA-S136S1-04)

North American Specifications for the Design of Cold Formed Steel Structural Members (using the Appendix B provisions applicable to Canada)

4.3.4.2.(1)

CSA

CAN/CSA-S157-05 / S157.1-05

Strength Design in Aluminum / Commentary  on CSA S157-05, Strength Design in Aluminum

4.3.5.1.(1)

CSA

S304.1-04

Design of Masonry Structures

Table 4.1.8.9.

 

 

 

4.3.2.1.(1)

CSA

S307-M1980

Load Test Procedure for Wood Roof Trusses for Houses and Small Buildings

9.23.13.11.(5)

CSA

CAN3-S367-M81

Air Supported Structures

4.4.1.1.(1)

CSA

CAN/CSA-S406-92

Construction of Preserved Wood Foundations

9.13.2.8.(1)

 

 

 

9.15.2.4.(1)

 

 

 

9.16.5.1.(1)

CSA

S413-07

Parking Structures

4.4.2.1.(1)

CSA

S478-95

Guideline on Durability in Buildings

5.1.4.2.(3)

CSA

Z32-04

Electrical Safety and Essential Electrical Systems in Health Care Facilities

3.2.7.3.(4)

 

 

 

3.2.7.6.(1)

 

 

 

3.7.5.1.(1)

CSA

CAN/CSA-Z91-M90

Safety Code for Window Cleaning Operations

4.4.4.1.(1)

CSA

CAN/CSA-Z240.2.1-92

Structural Requirements for Mobile Homes

9.1.1.9.(1)

 

 

 

9.12.2.2.(6)

 

 

 

9.15.1.3.(1)

CSA

CAN/CSA-Z240.3.1-92

Plumbing Requirements for Mobile Homes

9.1.1.9.(1)

CSA

CSA Z240.10.1-94

Site Preparation, Foundation and Anchorage of Mobile Homes

9.15.1.3.(1)

 

 

 

9.23.6.3.(1)

CSA

CAN/CSA-Z241 Series-03

Park Model Trailers

9.39.1.1.(1)

 

 

 

9.39.2.1.(1)

CSA

CAN/CSA-Z317.2-01

Special Requirements for Heating, Ventilation and Air Conditioning (HVAC) Systems in Health Care Facilities

6.2.1.1.(1)

CSA

CAN/CSA-Z7396.1-06

Medical Gas Piping Systems - Part 1: Pipelines for Medical Gases and Vacuum

3.7.5.2.(1)

CWC

2004

Engineering Guide for Wood Frame Construction

9.4.1.1.(1)

DBR

Building Research Note No. 126, 1979

Relation Between Thermal Resistance and Heat Storage in Building Enclosures

12.3.3.8.(1)

DBR

Technical Paper No. 194, May 1965

Fire Endurance of Protected Steel Columns and Beams

Table 11.5.1.1.A.

 

 

 

Table 11.5.1.1.B.

 

 

 

Table 11.5.1.1.C.

 

 

 

Table 11.5.1.1.D/E.

 

 

 

Table 11.5.1.1.F.

DBR

Technical Paper No. 207, October 1965

Fire Endurance of Unit Masonry Walls

Table 11.5.1.1.A.

 

 

 

Table 11.5.1.1.B.

 

 

 

Table 11.5.1.1.C.

 

 

 

Table 11.5.1.1.D/E.

 

 

 

Table 11.5.1.1.F.

DBR

Technical Paper No. 222, June 1966

Fire Endurance of Light Framed and Miscellaneous Assemblies

Table 11.5.1.1.A.

 

 

 

Table 11.5.1.1.B.

 

 

 

Table 11.5.1.1.C.

 

 

 

Table 11.5.1.1.D/E.

 

 

 

Table 11.5.1.1.F.

FINA

2005

Rules and Regulations - FINA Facilities Rules 2005-2009 - FR5 Diving Facilities

3.11.4.1.(17)

HI

2005

Hydronics Institute Manuals

6.2.1.1.(1)

HRAI

2005

Digest

6.2.1.1.(1)

 

 

 

6.2.3.5.(1)

 

 

 

6.2.4.3.(12)

HUD

Rehabilitation Guidelines 2000

Guideline on Fire Ratings of Archaic Materials and Assemblies

Table 11.5.1.1.A.

 

 

 

Table 11.5.1.1.B.

 

 

 

Table 11.5.1.1.C.

 

 

 

Table 11.5.1.1.D/E.

 

 

 

Table 11.5.1.1.F.

HVI

HVI 915-2006

Procedure for Loudness Rating of Residential Fan Products

9.32.3.9.(2)

 

 

 

Table 9.32.3.9.

HVI

HVI 916-2005

Airflow Test Procedure

9.32.3.9.(1)

ISO

ISO 8201; 1987(E)

Acoustics - Audible Emergency Evacuation Signal

3.2.4.18.(2)

MAH

Supplementary Standard SA-1, August 15, 2006

Objectives and Functional Statements Attributed to the Acceptable Solutions

1.2.1.1.(1) of Division A

 

 

 

1.2.1.1.(2) of Division A

MAH

Supplementary Standard SB-1, June 18, 2008

Climatic and Seismic Data

5.2.1.1.(1)

 

 

 

5.2.1.1.(2)

 

 

 

9.4.1.1.(3)

 

 

 

9.4.2.2.(1)

 

 

 

Table 9.25.1.2.

 

 

 

Table 9.32.3.10.A.

 

 

 

9.33.3.2.(1)

 

 

 

Table 12.3.2.1.

 

 

 

Table 12.3.4.2.A.

MAH

Supplementary Standard SB-2, June 9, 2009

Fire Performance Ratings

3.1.5.23.(1)

 

 

 

3.1.7.1.(2)

 

 

 

3.1.8.14.(2); 3.1.9.5.(1)

 

 

 

3.1.9.5.(2); 3.1.12.1.(3)

 

 

 

3.2.3.12.(1); 3.2.3.13.(4)

 

 

 

3.13.2.1.(8); 3.13.3.5.(1)

 

 

 

3.13.3.6.(2); 3.13.4.2.(7)

 

 

 

9.10.3.1.(1); 9.10.3.2.(1)

 

 

 

9.10.5.1.(4); 9.10.9.9.(1)

 

 

 

9.10.13.14.(1)

MAH

Supplementary Standard SB-3, June 18, 2008

Fire and Sound Resistance of Building Assemblies

9.10.3.1.(1)

 

 

 

9.10.5.1.(4)

 

 

 

9.11.2.1.(1)

 

 

 

9.11.2.1.(2)

MAH

Supplementary Standard SB-4, August 15, 2006

Measures for Fire Safety in High Buildings

3.2.6.9.(3)

 

 

 

3.2.6.10.(2)

 

 

 

3.2.6.14.(1)

MAH

Supplementary Standard SB-5, June 18, 2008

Approved Sewage Treatment Units

8.6.2.2.(5)

MAH

Supplementary Standard SB-6, August 15, 2006

Percolation Times and Soil Descriptions

8.2.1.2.(2)

MAH

Supplementary Standard SB-7, August 15, 2006

Guards for Housing and Small Buildings

9.8.8.2.(5)

MAH

Supplementary Standard SB-8, August 15, 2006

Design, Construction and Installation of Anchorage Systems for Fixed Access Ladders

3.6.1.5.(1)

MAH

Supplementary Standard SB-9, August 15, 2006

Requirements for Soil Gas Control

9.13.4.1.(1)

 

 

 

9.13.4.2.(2) to (4)

MAH

Supplementary Standard SB-10, June 18, 2008

Energy Efficiency Supplement

12.2.1.1.(2)

 

 

 

12.3.4.1.(1)

 

 

 

12.3.4.4.(3)

 

 

 

12.3.4.6.(1)

 

 

 

12.3.4.7.(3)

 

 

 

12.3.4.12.(1)

MAH

Supplementary Standard SB-11, August 15, 2006

Construction of Farm Buildings

1.3.1.2.(4) of Division A

MAH

Supplementary Standard

Energy Efficiency for Housing

12.2.1.1.(3)

 

SB-12, November 30, 2009

 

12.2.1.2.(3)

MAH

Supplementary Standard SC-1, August 15, 2006

Code of Conduct for Registered Code Agencies

3.7.4.1.(2) of Division C

MOE

Guidelines 1985, with Subsequent Revision

Guidelines for the Design of Sanitary Sewage Works, Storm Sewers, Water Storage Facilities, Water Distribution Systems, Servicing in areas subject to adverse conditions, Water Supply for small residential development and seasonally operated water supply

7.1.6.5.(1)

NFPA

2008 Publication

National Fire Codes

6.2.1.1.(1)

NFPA

13-2007

Installation of Sprinkler Systems

3.2.4.8.(2); 3.2.4.16.(1)

 

 

 

3.2.5.13.(1); 3.2.8.4.(7)

 

 

 

3.3.2.12.(3); 3.15.1.1.(3)

 

 

 

3.15.1.1.(4); 3.15.1.5.(2)

 

 

 

3.15.1.6.(2); 3.15.2.1.(1)

 

 

 

3.15.2.2.(1); 3.15.3.1.(1)

NFPA

13D-2007

Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes

3.2.5.13.(3)

NFPA

13R-2007

Installation of Sprinkler Systems in Residential Occupancies up to and including Four Stories in Height

3.2.5.13.(2)

NFPA

14-2007

Installation of Standpipe and Hose Systems

3.2.9.2.(1)

NFPA

20-2007

Installation of Stationary Pumps for Fire Protection

3.2.5.19.(1)

NFPA

24-2007

Installation of Fire Service Mains and Their Appurtenances

7.2.11.1.(1)

NFPA

80-2007

Fire Doors and Other Opening Protectives

3.1.8.5.(2)

 

 

 

3.1.8.10.(2)

 

 

 

3.1.8.12.(2)

 

 

 

3.1.8.12.(3)

 

 

 

3.1.8.14.(1)

 

 

 

3.13.3.1.(2)

 

 

 

9.10.13.1.(1)

NFPA

82-2004

Incinerators, Waste and Linen Handling Systems and Equipment

6.2.6.1.(1)

 

 

 

9.10.10.5.(2)

NFPA

96-2004

Ventilation Control and Fire Protection of Commercial Cooking Operations

6.2.2.6.(1)

NFPA

130-2007

Fixed Guideway Transit and Passenger Rail Systems

3.12.7.1.(1)

NFPA

211-2006

Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances

6.3.1.2.(2)

 

 

 

6.3.1.3.(1)

NFPA

214-2005

Water-Cooling Towers

6.2.3.14.(3)

NFPA

701-2004

Fire Tests for Flame Propagation of Textiles and Films

3.14.1.6.(1)

 

 

 

3.14.2.5.(1)

NLGA

2007

Standard Grading Rules for Canadian Lumber

1.4.1.2.(1) of Division A

 

 

 

9.3.2.1.(1)

 

 

 

Table 9.3.2.1.

 

 

 

Tables A-1 to A-10

NRCan

January 2005

Energuide for New Houses: Administrative and Technical Procedures

12.2.1.1.(3)

 

 

 

12.2.1.2.(3)

NSF/ANSI

46-2007

Evaluation of Components and Devices Used in Wastewater Treatment Systems

8.6.2.1.(2)

SMACNA

ANSI/SMACNA 006-2006, 3rd Edition 2005

HVAC Duct Construction Standards - Metal and Flexible

6.2.1.1.(1)

 

 

 

6.2.4.2.(3)

 

 

 

12.3.4.5.(1)

 

 

 

12.3.4.5.(2)

TC

 

Canadian Aviation Regulations - Part III

4.1.5.14.

TPIC

2007

Truss Design Procedures and Specifications for Light Metal Plate Connected Wood Trusses

9.23.13.11.(6)

UL

UL 300-2005

Fire Extinguishing Systems for Protection of Restaurant Cooking Areas

6.2.2.6.(2)

UL

UL 2034-2008

Single and Multiple Station Carbon Monoxide Alarms

6.2.3.12.(1)

 

 

 

9.33.4.3.(1)

ULC

CAN/ULC-S101-04

Fire Endurance Tests of Building Construction and Materials

3.1.5.12.(3)

 

 

 

3.1.5.12.(4)

 

 

 

3.1.5.12.(6)

 

 

 

3.1.7.1.(1)

 

 

 

3.1.11.7.(1)

 

 

 

3.2.3.8.(1)

 

 

 

3.2.6.9.(6)

ULC

CAN/ULC-S102-03

Test for Surface Burning Characteristics of Building Materials and Assemblies

3.1.5.25.(1)

 

 

 

3.1.12.1.(1)

ULC

CAN/ULC-S102.2-03

Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies

3.1.12.1.(2)

 

 

 

3.1.13.4.(1)

ULC

S102.3-M82

Fire Test of Light Diffusers and Lenses

3.1.13.4.(1)

ULC

CAN4-S104-M80

Fire Tests of Door Assemblies

3.1.8.4.(1)

 

 

 

3.2.6.9.(3)

ULC

CAN4-S105-M85

Fire Door Frames Meeting the Performance Required by CAN4-S104

9.10.13.6.(1)

ULC

CAN4-S106-M80

Fire Tests of Window and Glass Block Assemblies

3.1.8.4.(1)

ULC

CAN/ULC-S107-03

Fire Tests of Roof Coverings

3.1.15.1.(1)

ULC

CAN/ULC-S109-03

Flame Tests of Flame-Resistant Fabrics and Films

3.1.16.1.(1)

 

 

 

3.14.1.6.(1)

 

 

 

3.14.2.5.(1)

 

 

 

6.2.3.17.(1)

 

 

 

6.2.3.18.(1)

 

 

 

6.2.4.9.(1)

ULC

CAN/ULC-S110-M86

Tests for Air Ducts

6.2.3.2.(2)

 

 

 

6.2.3.2.(4)

ULC

ULC-S111-95

Fire Tests for Air Filter Units

6.2.3.13.(1)

 

 

 

6.2.4.14.(1)

ULC

CAN/ULC-S112-M90

Fire Test of Fire-Damper Assemblies

3.1.8.4.(1)

ULC

CAN/ULC-S112.1-M90

Leakage Rated Dampers for Use in Smoke Control Systems

6.2.3.9.(3)

ULC

CAN/ULC-S112.2-07

Fire Test of Ceiling Firestop Flap Assemblies

3.1.9.5.(2)

 

 

 

3.6.4.3.(2)

ULC

CAN/ULC-S113-07

Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies

9.10.13.2.(1)

ULC

CAN/ULC-S114-05

Test for Determination of Non-Combustibility in Building Materials

1.4.1.2.(1) of Division A

ULC

CAN/ULC-S115-05

Fire Tests of Firestop Systems

3.1.5.16.(3)

 

 

 

3.1.9.1.(1)

 

 

 

3.1.9.1.(2)

 

 

 

3.1.9.4.(4)

 

 

 

9.10.9.7.(3)

ULC

CAN/ULC-S124-06

Test for the Evaluation of Protective Coverings for Foamed Plastic

3.1.5.12.(2)

ULC

CAN/ULC-S126-06

Test for Fire Spread Under Roof-Deck Assemblies

3.1.14.1.(1)

 

 

 

3.1.14.2.(1)

ULC

CAN/ULC-S134-92

Fire Test of Exterior Wall Assemblies

3.1.5.5.(1)

ULC

CAN/ULC-S135-04

Test Method for the Determination of Combustibility Parameters of Building Materials Using an Oxygen Consumption Calorimeter (Cone Calorimeter)

3.1.5.1.(2)

ULC

CAN/ULC-S138-06

Fire Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration

3.1.5.12.(7)

ULC

ULC-S139-00

Fire Test for Evaluation of Integrity of Electrical Cables

3.2.7.10.(2)

ULC

S505-1974

Fusible Links for Fire Protection Service

3.1.8.9.(1)

ULC

S513-1978

Threaded Couplings for 38 mm and 65 mm Fire Hose

3.2.9.2.(7)

ULC

CAN/ULC-S524-06

Installation of Fire Alarm Systems

3.2.4.5.(1)

ULC

CAN/ULC-S531-02

Smoke Alarms

3.2.4.21.(1)

 

 

 

9.10.19.1.(1)

ULC

CAN/ULC-S537-04

Verification of Fire Alarm Systems

3.2.4.5.(2)

ULC

CAN/ULC-S543-09

Internal Lug Quick Connect Couplings for Fire Hose

3.2.9.2.(7)

ULC

CAN/ULC-S553-02

Installation of Smoke Alarms

3.2.4.21.(7)

ULC

CAN/ULC-S561-03

Installation and Services for Fire Signal Receiving Centres and Systems

3.2.4.7.(4)

ULC

CAN/ULC-S610-M87

Factory-Built Fireplaces

9.22.8.1.(1)

ULC

ULC-S628-93

Fireplace Inserts

9.22.10.1.(1)

ULC

CAN/ULC-S629-M87

650ºC Factory-Built Chimneys

9.21.1.2.(1)

ULC

CAN/ULC-S639-M87

Steel Liner Assemblies for Solid Fuel-Burning Masonry Fireplaces

9.22.2.3.(1)

ULC

CAN/ULC-S701-05

Thermal Insulation, Polystyrene, Boards and Pipe Covering

Table 5.10.1.1.

 

 

 

9.15.4.1.(1)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.25.2.2.(1)

 

 

 

9.25.2.2.(4)

ULC

CAN/ULC-S702-97

Mineral Fibre Thermal Insulation for Buildings

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

 

 

 

9.25.2.2.(1)

ULC

CAN/ULC-S703-01

Cellulose Fibre Insulation (CFI) for Buildings

Table 5.10.1.1.

 

 

 

9.25.2.2.(1)

ULC

CAN/ULC-S704-03

Thermal Insulation, Polyurethane and Polyisocyanurate Boards, Faced

Table 5.10.1.1.

 

 

 

Table 9.23.16.2.A.

 

 

 

9.25.2.2.(1)

ULC

CAN/ULC-S705.1-01

Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium Density - Material Specification

Table 5.10.1.1.

 

 

 

9.25.2.2.(1)

ULC

CAN/ULC-S705.2-98

Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium Density, Installers’s Responsibilities - Specification

Table 5.10.1.1.

 

 

 

9.25.2.2.(1)

 

 

 

9.25.2.5.(1)

ULC

CAN/ULC-S706-02

Wood Fibre Thermal Insulation for Buildings

Table 5.10.1.1.

 

 

 

9.23.15.7.(3)

 

 

 

Table 9.23.16.2.A.

 

 

 

9.25.2.2.(1)

 

 

 

9.29.8.1.(1)

ULC

ULC/ORD-C263.1-99

Sprinkler-Protected Window Systems

3.1.8.18.(1)

ULC

ULC/ORD-C199P-02

Combustible Piping for Sprinkler Systems

3.2.5.14.(2)

 

 

 

3.2.5.14.(5)

ULC

ULC/ORD-C1254.6-1995

Fire Testing of Restaurant Cooking Area Fire Extinguishing System Units

6.2.2.6.(2)

ULC

ULC/ORD-C2024-02

Fire Tests For Optical Fibre Cable Raceway

3.1.5.20.(1)

 

 

 

3.6.4.3.(1)

13. Clause 3.1.5.5.(1)(b) of Division B of the Regulation is amended by striking out “Sentence 3.1.5.11.(3)” and substituting “Sentence 3.1.5.12.(3)”.

14. (1) Clause 3.1.5.12.(4)(a) of Division B of the Regulation is amended by adding “or” at the end of Subclause (i) and by revoking Subclauses (ii) to (vii) and substituting the following:

(ii) Reserved

(iii) Reserved

(iv) Reserved

(v) Reserved

(vi) Reserved

(vii) Reserved

(viii) ASTM C1396 / C1396M, “Gypsum Board”,

(2) Clause 3.1.5.12.(7)(e) of Division B of the Regulation is amended by striking out “ULC/ORD-C376, “Fire Growth of Foamed Plastic Insulated Building Panels in a Full-Scale Room Configuration”” and substituting “CAN/ULC-S138, “Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration””.

15. Sentence 3.1.5.20.(1) of Division B of the Regulation is amended by adding “or Clause 6.16 of CSA C22.2 No 211.0, “General Requirements and Methods of Testing for Nonmetallic Conduit”” before “(FT4 rating)”.

16. Sentence 3.1.7.1.(1) of Division B of the Regulation is amended by striking out “CAN/ULC-S101-M” and substituting “CAN/ULC-S101”.

17. Clause 3.1.8.5.(2)(a) of Division B of the Regulation is amended by striking out “NFPA 80, “Standard for Fire Doors and Fire Windows”” and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

18. Sentence 3.1.8.10.(2) of Division B of the Regulation is amended by striking out “NFPA 80, “Fire Doors and Fire Windows”” and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

19. (1) Clause 3.1.8.12.(2)(d) of Division B of the Regulation is amended by striking out “Appendix B of NFPA 80, “Fire Doors and Fire Windows”” at the end and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

(2) Sentence 3.1.8.12.(3) of Division B of the Regulation is amended by striking out “Appendix B of NFPA 80, “Fire Doors and Fire Windows”” in the portion before Clause (a) and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

(3) Sentence 3.1.8.12.(4) of Division B of the Regulation is amended by striking out “Except as required by Sentence (5), (6) and (7)” at the beginning in the portion before Clause (a) and substituting “Except as required by Sentences (5), (6) and (7)”.

20. Sentence 3.1.8.14.(1) of Division B of the Regulation is amended by striking out “NFPA 80, “Fire Doors and Fire Windows”” at the end and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

21. The heading to Article  3.1.13.3. of Division B of the Regulation is revoked and the following substituted:

3.1.13.3. Plumbing Fixtures and Bathrooms Finishes

22. Sentence 3.1.13.5.(1) of Division B of the Regulation is amended by striking out “building” and substituting “storey”.

23. Sentence 3.1.13.7.(2) of Division B of the Regulation is amended by striking out “Sentence 3.2.6.4.(1)” at the end and substituting “Sentences 3.2.4.9.(2) and 3.2.4.16.(1)”.

24. Clause 3.1.14.2.(1)(b) of Division B of the Regulation is amended by striking out “3.2.2.69.(2), and” and substituting “3.2.2.70.(2) and”.

25. Clause 3.2.2.42.(2)(c) of Division B of the Regulation is amended by striking out “not less 1 h” and substituting “not less than 1 h”.

26. The heading to Table 3.2.2.44. of Division B of the Regulation, as made by section 5 of Ontario Regulation 205/08, is amended by striking out “Forming Part of Sentence 3.2.2.43.(1)” and substituting “Forming Part of Sentence 3.2.2.44.(1)”.

27. Clause 3.2.2.72.(2)(b) of Division B of the Regulation is amended by striking out “fire-resistance rating” in the portion before Subclause (i) and substituting “fire-resistance rating”.

28. Sentence 3.2.3.16.(1) of Division B of the Regulation is amended by striking out “Sentences (2) and (3)” in the portion before Clause (a) and substituting “Sentences (2) to (4)”.

29. Sentence 3.2.5.17.(1) of Division B of the Regulation is amended by striking out “Part 6” and substituting “Part 6 of Division B”.

30. Clause 3.2.7.3.(2)(b) of Division B of the Regulation is revoked and the following substituted:

(b) on a shelf and rack storage system, in locations described in Sentence 3.16.1.5.(2).

31. Clause 3.2.7.9.(1)(d) of Division B of the Regulation is amended by striking out “Article 3.2.6.10.” at the end and substituting “Article 3.2.6.6.”

32. (1) Sentence 3.2.7.10.(1) of Division B of the Regulation is amended by striking out “Articles 3.2.6.2. to 3.2.6.8., and” and substituting “Articles 3.2.6.2. to 3.2.6.13. and 3.2.7.3. and”.

(2) Sentence 3.2.7.10.(1) of Division B of the Regulation is amended by striking out “Articles 3.2.6.2. to 3.2.6.13.” and substituting “Articles 3.2.6.2. to 3.2.6.8.”.

33. (1) Clause 3.2.8.2.(1)(c) of Division B of the Regulation is amended by striking out “Sentence 3.2.1.1.(3) or (5)” at the end and substituting “Sentence 3.2.1.1.(3) or (8)”.

(2) Clause 3.2.8.2.(1)(e) of Division B of the Regulation is amended by striking out “Sentence 3.2.1.1.(8)” at the end and substituting “Sentence 3.2.1.1.(7)”.

(3) Sentence 3.2.8.2.(5) of Division B of the Regulation is amended by striking out “Articles 3.2.8.3. to 3.2.3.11.” in the portion before Clause (a) and substituting “Articles 3.2.8.3. to 3.2.8.11.”.

34. Subclause 3.2.8.8.(1)(b)(ii) of Division B of the Regulation is amended by striking out “Sentences (5), (6) and (7) of Article 3.2.8.9.” and substituting “Sentences 3.2.8.9.(3), (4), (6) and (7)”.

35. (1) Sentence 3.3.1.4.(3) of Division B of the Regulation is amended by striking out “care occupancy or detention occupancy or a residential occupancy” at the end and substituting “care or detention occupancy or residential occupancy”.

(2) Clause 3.3.1.4.(4)(a) of Division B of the Regulation is amended by striking out “Sentences 3.3.3.5.(10) and 3.3.4.2.(1)” and substituting “Sentences 3.3.3.5.(9) and 3.3.4.2.(1)”.

36. (1) Subclause 3.3.1.7.(1)(a)(i) of Division B of the Regulation is amended by striking out “Sentences 3.2.6.9.(4) to (6)” at the end and substituting “Sentences 3.2.6.5.(4) to (6)”.

(2) Subclause 3.3.1.7.(1)(a)(ii) of Division B of the Regulation is amended by striking out “Clause 3.2.6.9.(3)(b) or (c)” and substituting “Clause 3.2.6.5.(3)(b) or (c)”.

37. Sentence 3.3.2.5.(1) of Division B of the Regulation is amended by striking out “building” and substituting “floor area”.

38. Sentence 3.3.3.2.(5) of Division B of the Regulation is amended by striking out “need to be provided” and substituting “need not be provided”.

39. Sentence 3.3.3.5.(9) of Division B of the Regulation is amended by striking out “Sentences (10) and (12)” and substituting “Sentences (10) and (11)”.

40. Clause 3.3.4.4.(9)(a) of Division B of the Regulation, as made by subsection 9 (4) of Ontario Regulation 205/08, is amended by striking out “of adjacent ground level” and substituting “above adjacent ground level”.

41. Sentence 3.4.2.2.(2) of Division B of the Regulation is amended by striking out “Article 3.2.8.1.” and substituting “Article 3.2.8.2.”.

42. Sentence 3.4.4.4.(1) of Division B of the Regulation is amended by striking out “and” at the end of Clause (d), by adding “and” at the end of Clause (e) and by adding the following Clause:

(f) a sprinkler protected glazed wall assembly conforming to Article 3.1.8.18.

43. Sentence 3.4.5.1.(1) of Division B of the Regulation is amended by striking out “Except as required by Sentences (7) and (9)” and substituting “Except as provided in Sentences (7) and (9)”.

44. Sentence 3.4.6.4.(1) of Division B of the Regulation is amended by striking out “A ramp or stairway” at the beginning and substituting “A stairway”.

45. Clause 3.4.6.15.(4)(d) of Division B of the Regulation is amended by striking out “Sentence 3.2.6.12.(1)” at the end and substituting “Sentence 3.2.6.7.(1)”.

46. Sentence 3.5.1.1.(2) of Division B of the Regulation is amended by striking out “Articles 3.2.6.8. and 3.2.6.9.” at the end and substituting “Articles 3.2.6.4. and 3.2.6.5.”.

47. Sentence 3.5.2.2.(1) of Division B of the Regulation is amended by striking out “CSA B44, “Safety Code for Elevators”” at the end and substituting “ASME A17.1 / CSA B44, “Safety Code for Elevators and Escalators””.

48. Sentence 3.5.3.1.(2) of Division B of the Regulation is amended by striking out “Article 3.2.6.9.” and substituting “Article 3.2.6.5.”.

49. Sentence 3.7.5.1.(1) of Division B of the Regulation is amended by striking out ““Essential Electrical Systems in Health Care Facilities”” at the end and substituting ““Electrical Safety and Essential Electrical Systems in Health Care Facilities””.

50. Sentence 3.7.5.2.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-Z305.1, “Nonflammable Medical Gas Piping Systems”” at the end and substituting “CAN/CSA-Z7396.1, “Medical Gas Piping Systems - Part 1: Pipelines for Medical Gases and Vacuum””.

51. The heading to Table 3.8.2.1. of Division B of the Regulation is amended by striking out “Forming Part of Sentence 3.8.2.1.(4)” and substituting “ Forming Part of Sentence 3.8.2.1.(3)”.

52. Sentence 3.8.3.3.(6) of Division B of the Regulation is amended by striking out “Sentence (4) and (5)” and substituting “Sentences (4) and (5)”.

53. Subclause 3.8.3.4.(1)(e)(v) of Division B of the Regulation is amended by striking out “40 mm” and substituting “50 mm”.

54. Sentence 3.8.3.11.(1) of Division B of the Regulation is amended by striking out “and” at the end of Clause (e) and by adding “and” at the end of Subclause (f)(iii).

55. Sentence 3.10.3.4.(1) of Division B of the Regulation is amended by striking out “Sentences (2) to (4)” and substituting “Sentences (2) and (3)”.

56. Sentence 3.11.3.1.(1) of Division B of the Regulation is amended by striking out “Sentences (2) to (25)” at the end and substituting “Sentences (2) to (26)”.

57. Sentence 3.13.3.1.(2) of Division B of the Regulation is amended by striking out “Table 2-8A of NFPA 80, “Fire Doors and Windows”” at the end and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

58. Note (1) to Table 4.1.5.12. of Division B of the Regulation is revoked and the following substituted:

(1) See ASME A17.1 / CSA B44, “Safety Code for Elevators and Escalators.”

59. Note (1) to Table 4.1.8.6. of Division B of the Regulation is amended by striking out “One-storey” at the beginning and substituting “One-storey”.

60. (1) The heading to Article 4.1.8.11. of Division B of the Regulation is amended by striking out “Article 4.1.8.6.” at the end and substituting “Article 4.1.8.7.”.

(2) Sentence 4.1.8.11.(7) of Division B of the Regulation is amended by striking out,

and substituting,

61. (1) Table 4.1.8.17. of Division B of the Regulation is amended by striking out,

 

4

Floors and roofs acting as diaphragms(2)

-

-

2.50

and substituting,

 

4

Floors and roofs acting as diaphragms(2)

-

-

-

(2) Table 4.1.8.17. of Division B of the Regulation is amended by striking out,

 

14

Flat bottom tanks (including contents) attached directly to a floor at or below grade within a building containing toxic or explosive materials, materials having a having a flash point below 38°C or fire fighting fluids

1.00

1.00

3.00

and substituting,

 

14

Flat bottom tanks (including contents) attached directly to a floor at or below grade within a building containing toxic or explosive materials, materials having a flash point below 38°C or fire fighting fluids

1.00

1.00

2.50

 

62. Clauses 4.2.3.8.(1)(c) and (d) of Division B of the Regulation are revoked and the following substituted:

(c) ASTM A1008 / A1008M , “Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable”,

(d) ASTM A1011 / A1011M, “Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength”, or

63. The heading to Article 4.2.4.9. of Division B of the Regulation is amended by striking out “Groundwater Level Charge” and substituting “Groundwater Level Change”.

64. Sentence 4.3.1.2.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-O177-M” and substituting “CSA O177-M”.

65. Sentence 4.3.5.1.(1) of Division B of the Regulation is amended by striking out “CAN3-S157, “Strength Design in Aluminum”” and substituting “CAN/CSA-S157 / S157.1, “Strength Design in Aluminum/Commentary on CSA S157-05, Strength Design in Aluminum””.

66. Sentence 4.4.2.1.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-S413” and substituting “CSA S413”.

67. Sentence 4.4.4.1.(1) of Division B of the Regulation is amended by striking out “Article 1.3.2.2.” and substituting “Article 1.1.2.2.”.

68. Article 4.4.5.1. of Division B of the Regulation is revoked and the following substituted:

4.4.5.1.  Liquid Manure Storage Tanks

(1) Reserved

(2) Liquid manure storage tanks shall be constructed of steel, reinforced concrete or prestressed concrete.

(3) Liquid manure storage tank walls, bases and appurtenances, including piping for the conveyance of liquid manure and associated connections and joints, shall be designed and constructed to prevent leakage of contents.

(4) Concrete for liquid manure storage tanks shall,

(a) be made from HS or HSb cement,

(b) have a 28-day strength of at least 32 MPa, and

(c) have a water/cement materials ratio of not more than 0.45.

(5) Liquid manure storage tanks shall be placed on undisturbed soil free of any organic, deleterious and extraneous materials and capable of supporting the superimposed design loads from the tanks.

(6) Where granular fills are used between the bases of liquid manure storage tanks and the undisturbed soil, the granular fills shall be compacted to a Standard Proctor density of not less than 95 per cent.

69. Sentence 5.1.5.1.(1) of Division B of the Regulation is revoked and the following substituted:

(1) Structural and fire safety requirements shall comply with other Parts of the Code.

70. Subclause 5.8.2.3.(2)(b)(ii) of Division B of the Regulation is amended by striking out “CAN/CGSB 37.22-M” at the beginning and substituting “CAN/CGSB-37.22-M”.

71. Clause 5.9.1.1.(1)(b) of Division B of the Regulation is revoked and the following substituted:

(b) ASTM E336, “Measurement of Airborne Sound Attenuation Between Rooms in Buildings”.

72. Sentence 5.9.1.2.(2) of Division B of the Regulation is amended by striking out “should” and substituting “sound”.

73. (1) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C36 / C36M

Gypsum Wallboard

ASTM

C37 / C37M

Gypsum Lath

ASTM

C79 / C79M

Treated Core and Nontreated Core Gypsum Sheathing Board

(2) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C442 / C442M

Gypsum Backing Board, and Gypsum Coreboard, and Gypsum Shaftliner Board

(3) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C588 / C588M

Gypsum Base for Veneer Plasters

ASTM

C630 / C630M

Water-Resistant Gypsum Backing Board

(4) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C931 / C931M

Exterior Gypsum Soffit Board

ASTM

C960 / C960M

Predocorated Gypsum Board

(5) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C1178 / C1178M

Glass Mat Water-Resistant Gypsum Board Backing Panel

and substituting,

 

ASTM

C1178 / C1178M

Coated Glass Mat Water-Resistant Gypsum Board Backing Panel

(6) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

ASTM

C1395 / C1395M

Gypsum Ceiling Board

(7) Table 5.10.1.1. of Division B of the Regulation is amended by adding the following:

 

ASTM

E2190

Insulating Glass Unit Performance and Evaluation

(8) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

BNQ

NQ3624-115

Polyethylene (PE) Pipe and Fittings - Flexible Corrugated Pipes for Drainage - Characteristics and Test Methods

and substituting,

 

BNQ

BNQ3624-115

Polyethylene (PE) Pipe and Fittings - Flexible Pipes for Drainage - Characteristics and Test Methods

(9) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

CSA

CAN/CSA-A123.1-M

Asphalt Shingles Made from Organic Felt and Surfaced with Mineral Granules

CSA

A123.2

Asphalt Coated Roofing Sheets

CSA

CAN/CSA-A123.3

Asphalt Saturated Organic Roofing Felt

and substituting,

 

CSA

A123.1/123.5

Asphalt Shingles Made from Organic Felt and Surfaced with Mineral Granules / Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

CSA

CAN/CSA-A123.2

Asphalt Coated Roofing Sheets

CSA

A123.3

Asphalt Saturated Organic Roofing Felt

(10) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

CSA

CAN/CSA-A123.5

Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

CSA

A123.17

Asphalt-Saturated Felted Glass-Fibre Mat for Use in Construction of Built-Up Roofs

and substituting,

 

CSA

A123.17

Asphalt Glass Felt Used in Roofing and Waterproofing

(11) Table 5.10.1.1. of Division B of the Regulation is amended by striking out,

 

CSA

CAN/CSA-A220.0-M

Performance of Concrete Roof Tiles

CSA

CAN/CSA-A220.1-M

Installation of Concrete Roof Tiles

and substituting,

 

CSA

CAN/CSA-A220.0

Performance of Concrete Roof Tiles

CSA

CAN/CSA-A220.1

Installation of Concrete Roof Tiles

74. Sentence 6.2.2.1.(2) of Division B of the Regulation is amended by striking out “ANSI/ASHRAE 62” and substituting “ANSI/ASHRAE 62.1”.

75. Sentence 6.2.3.4.(7) of Division B of the Regulation is amended by striking out “closures” at the end and substituting “closures”.

76. Sentence 6.2.3.8.(15) of Division B of the Regulation is amended by striking out “ANSI/ASHRAE 62” and substituting “ANSI/ASHRAE 62.1”.

77. The heading to Table 6.2.9.3. of Division B of the Regulation is amended by striking out “Forming Part of Sentence 6.2.9.3.(1)” and substituting “Forming Part of Sentences 6.2.7.1.(1), 6.2.8.1.(2) and 6.2.9.3.(1)”.

78. Article 7.1.5.4. of Division B of the Regulation is revoked and the following substituted:

7.1.5.4.  Separate Services

(1) Except as provided in Sentences (2) and (3), piping in any building shall be connected to the public services separately from piping of any other building.

(2) An ancillary building on the same property as the main building may be served by the same service.

(3) Water service pipes or building sewers serving buildings located on the same property may connect into a private water supply or a private sewer conforming to Article 7.1.5.5.

(4) No plumbing serving a dwelling unit shall be installed in or under another unit of the building unless the piping is located in a tunnel, pipe corridor, common basement or parking garage, so that the piping is accessible for servicing and maintenance throughout its length without encroachment on any private living space, but this Sentence does not prevent plumbing serving a unit located above another unit from being installed in or under the lower unit.

79. Sentence 7.2.3.3.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-B125, “Plumbing Fittings”” and substituting “ASME A112.18.2 / CAN/CSA-B125.2, “Plumbing Waste Fittings””.

80. Sentence 7.2.5.5.(1) of Division B of the Regulation is amended by striking out ““Polyethylene Pipe, Tubing and Fittings for Cold Water Pressure Services”” at the end and substituting ““Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services””.

81. Sentence 7.2.5.7.(1) of Division B of the Regulation is amended by striking out ““Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications”” at the end and substituting ““Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications””.

82. Sentence 7.2.5.8.(1) of Division B of the Regulation is revoked and the following substituted:

(1) PVC water pipe, fittings and solvent cement shall be certified to CAN/CSA-B137.3, “Rigid Polyvinylchloride (PVC) Pipe for Pressure Applications” or CAN/CSA-B137.2, “Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications”, and have a minimum pressure rating of 1 100 kPa.

83. Article 7.2.5.9. of Division B of the Regulation is revoked and the following substituted:

7.2.5.9. CPVC Pipe, Fittings and Solvent Cements

(1) CPVC hot and cold water pipe, fittings and solvent cements shall be certified to CAN/CSA-B137.6, “Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”.

(2) The design temperature and design pressure of a CPVC piping system shall conform to CAN/CSA-B137.6, “Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”.

84. Clauses 7.2.5.10.(1)(b) to (j) of Division B of the Regulation are revoked and the following substituted:

(b) CAN/CSA-B181.1, “Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings”,

(c) CAN/CSA-B181.2, “Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings”,

(d) CAN/CSA-B182.1, “Plastic Drain and Sewer Pipe and Pipe Fittings”,

(e) CAN/CSA-B182.2, “PSM Type Polyvinylchloride (PVC) Sewer Pipe and Fittings”,

(f) CAN/CSA-B182.4, “Profile Polyvinylchloride (PVC) Sewer Pipe and Fittings”,

(g) CAN/CSA-B182.6, “Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-Proof Sewer Applications”,

(h) CAN/CSA-B182.7, “PSM Type Multilayer Polyvinylchloride (PVC) Sewer Pipe Having Reprocessed-Recycled Content”,

(i) CAN/CSA-B137.2, “Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications”, or

(j) CAN/CSA-B137.3, “Rigid Polyvinylchloride (PVC) Pipe for Pressure Applications”.

85. Clauses 7.2.5.11.(1)(a) and (b) of Division B of the Regulation are revoked and the following substituted:

(a) CAN/CSA-B181.1, “Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings”, or

(b) CAN/CSA-B181.2, “Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings”.

86. (1) Clauses 7.2.5.12.(1)(b) and (c) of Division B of the Regulation are revoked and the following substituted:

(b) CAN/CSA-B181.1, “Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings”, or

(c) CAN/CSA-B181.2, “Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings”.

(2) Clauses 7.2.5.12.(2)(b) and (c) of Division B of the Regulation are revoked and the following substituted:

(b) CAN/CSA-B181.1, “Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings”,

(c) CAN/CSA-B181.2, “Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings”,

(3) Clause 7.2.5.12.(2)(e) of Division B of the Regulation is revoked and the following substituted:

(e) CAN/CSA-B182.2, “PSM Type Polyvinylchloride (PVC) Sewer Pipe and Fittings”.

87. (1) Sentence 7.2.5.13.(1) of Division B of the Regulation is amended by striking out ““Polyethylene/Aluminum/ Polyethylene Composite Pressure Pipe Systems”” at the end and substituting ““Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems””.

(2) Sentence 7.2.5.13.(2) of Division B of the Regulation is revoked and the following substituted:

(2) Except as provided in Sentences (3) and (4), PE/AL/PE pipe and fittings shall not be used in a hot water system.

(3) PE/AL/PE pipe with a pressure rating of 690 kPa or greater at 82ºC shall be permitted in a hot water system.

(4) PE/AL/PE pipe with a pressure rating of 690 kPa or greater at 82ºC shall be used with fittings that conform to CAN/CSA-B137.10, “Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems”, in a hot water system.

88. Sentence 7.2.5.14.(1) of Division B of the Regulation is amended by striking out ““Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe Systems”” at the end and substituting ““Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems””.

89. Sentence 7.2.6.4.(3) of Division B of the Regulation is revoked and the following substituted:

(3) Cast iron fittings for cast iron or ductile-iron water pipes shall conform to ANSI/AWWA C110/A21.10, “Ductile-Iron and Gray-Iron Fittings for Water”.

90. Sentence 7.2.6.5.(1) of Division B of the Regulation is amended by striking out ““Gray Iron Threaded Fittings”” at the end and substituting ““Gray Iron Threaded Fittings, Classes 125 and 250””.

91. Sentence 7.2.6.6.(1) of Division B of the Regulation is amended by striking out ““Malleable Iron Threaded Fittings”” at the end and substituting ““Malleable Iron Threaded Fittings, Classes 150 and 300””.

92. Table 7.2.7.4. of Division B of the Regulation is amended by striking out “Type of Copper Tube or Pipe” in the heading under Column 1 and substituting “Type of Copper Tube or Pipe”.

93. Clause 7.2.8.1.(1)(c) of Division B of the Regulation is revoked and the following substituted:

(c) CAN/CSA-B181.3, “Polyolefin and Polyvinylidene (PVDF) Laboratory Drainage Systems”.

94. (1) The heading to Article 7.2.10.1. of Division B of the Regulation is revoked and the following substituted:

7.2.10.1. Floor Flanges

(2) Sentence 7.2.10.1.(2) of Division B of the Regulation is amended by striking out ““ABS Drain, Waste, and Vent Pipe and Pipe Fittings”” at the end and substituting ““Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings””.

(3) Sentence 7.2.10.1.(3) of Division B of the Regulation is amended by striking out ““PVC Drain, Waste, and Vent Pipe and Pipe Fittings”” at the end and substituting ““Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings””.

95. Article 7.2.10.6. of Division B of the Regulation is revoked and the following substituted:

7.2.10.6. Supply and Waste Fittings

(1) Supply fittings shall conform to ASME A112.18.1 / CAN/CSA-B125.1, “Plumbing Supply Fittings” or CAN/CSA-B125.3, “Plumbing Fittings”.

(2) Waste fittings shall conform to ASME A112.18.2 / CAN/CSA-B125.2, “Plumbing Waste Fittings”.

96. Sentence 7.2.10.10.(2) of Division B of the Regulation is revoked and the following substituted:

(2) Back-siphonage preventers (anti-siphon fill valves) for tank type water closets shall be certified to CAN/CSA-B125.3, “Plumbing Fittings”.

97. Sentence 7.2.10.13.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-F379.1, “Solar Domestic Hot Water Systems (Liquid to Liquid Heat Transfer)”” at the end and substituting “CSA F379.1, “Packaged Solar Domestic Hot Water Systems (Liquid-to-Liquid Heat Transfer) for All-Season Use””.

98. Table 7.2.11.2. of Division B of the Regulation is revoked and the following substituted:

Table 7.2.11.2.
Water Service Pipe and Fire Service Main Materials

Forming Part of Sentence 7.2.11.2.(1)

 

Column 1

Column 2

Column 3

Material

Standard

Limitations

Polyethylene pipe and fittings

Certified to Series 160 of CAN/CSA-B137.1, “Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services”

 

Crosslinked polyethylene pressure pipe or tube and fittings

Certified to CAN/CSA-B137.5, “Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications”

 

PVC pipe and fittings

Certified to CAN/CSA-B137.3, “Rigid Polyvinylchloride (PVC) Pipe for Pressure Applications”, or certified to CAN/CSA-B137.2, “Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications”

Pipe and fittings must have a rated working pressure of 1 100 kPa or more

CPVC pipe and fittings

Certified to CAN/CSA-B137.6, “Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”

The design temperature and pressure shall conform to the requirements of the CAN/CSA-B137.6, “Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”

Cast iron water pipe

Conform to ANSI/AWWA C151/A21.51, “Ductile-Iron Pipe, Centrifugally Cast for Water”

Pipe shall have a cement mortar lining conforming to ANSI/AWWA C104/A21.4, “Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water”

Iron fittings for cast iron or ductile-iron water pipes

Conform to ANSI/AWWA C110/A21.10, “Ductile-Iron and Gray-Iron Fittings for Water”

Pipe shall have a cement mortar lining conforming to ANSI/AWWA C104/A21.4, “Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water”

Rubber gasket joints for cast iron and ductile-iron water pipes

Conform to ANSI/AWWA C111/A21.11, “Rubber Gasket Joints for Ductile-Iron Pressure Pipe and Fittings”

 

Screwed cast iron water fittings

Conform to ANSI/ASME B16.4, “Gray Iron Threaded Fittings, Classes 125 and 250”

Screwed cast iron water fittings shall be cement-mortar lined or galvanized

Type K soft copper tube

Certified to ASTM B88, “Seamless Copper Water Tube”

 

Solder-joint fittings for copper water systems

Conform to ANSI B16.18, “Cast Copper Alloy Solder Joint Pressure Fittings”, or conform to ANSI/ASME B16.22, “Wrought Copper and Copper Alloy Solder-Joint Pressure Fittings”

Solder-joint fittings not made by casting or the wrought process shall conform to the applicable requirements of ANSI B16.18, “Cast Copper Alloy Solder-Joint Pressure Fittings”

Flared-joint fittings for copper water systems

Conform to ANSI/ASME B16.26, “Cast Copper Alloy Fittings for Flared Copper Tubes”

Flared-joint fittings not made by casting shall conform to ANSI/ASME B16.26, “Cast Copper Alloy Fittings for Flared Copper Tubes”

PE/AL/PE pipe and fittings

Certified to CAN/CSA B137.9, “Polyethylene/Aluminum/ Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems”

 

PEX/AL/PEX pipe and fittings

Certified to CAN/CSA B137.10, “Crosslinked Polyethylene/ Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems”

 

99. (1) Sentence 7.3.5.7.(1) of Division B of the Regulation is amended by striking out “Except as permitted in Sentence (2)” at the beginning and substituting “Except as permitted in Sentences (2) and (3)”.

(2) Sentence 7.3.5.7.(3) of Division B of the Regulation is revoked and the following substituted:

(3) A buried water service pipe may pass under a building drain or building sewer if,

(a) a vertical separation of not less than 500 mm is provided between the invert of the building drain or building sewer and the crown of the water service pipe,

(b) adequate structural support is provided for the building drain or building sewer to prevent excessive deflection of joints and settling, and

(c) the length of the water service pipe is located so that there are no joints within 2 440 mm measured horizontally from the intersection with the building drain or building sewer.

(4) A buried water service pipe shall be constructed of a single run of pipe with no joints or fittings between the street line or source of supply on the property and the inside face of the building if the water service pipe is less than 15 m from,

(a) a private sewage disposal system, or

(b) a source of pollution other than a private sewage disposal system.

100. Sentence 7.4.2.1.(1) of Division B of the Regulation is amended by adding “and” at the end of Subclause (d)(vii), by striking out Clauses (e), (f) and (g) and substituting the following:

(e) Reserved

(f) Reserved

(g) Reserved

101. Sentence 7.4.3.6.(1) of Division B of the Regulation is amended by striking out “CSA B44, “Safety Code for Elevators”” at the end and substituting “ASME A17.1 / CSA B44, “Safety Code for Elevators and Escalators””.

102. Subclauses 7.4.6.4.(2)(a)(ii) and (iii) of Division B of the Regulation are revoked and the following substituted:

(ii) CAN/CSA-B181.1, “Acrylonitrile-Butadiene-Styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings”,

(iii) CAN/CSA-B181.2, “Polyvinylchloride (PVC) and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings”, or

103. Sentence 7.4.7.2.(6) of Division B of the Regulation is amended by striking out “storm drainage piping” and substituting “exterior storm drainage pipe”.

104. Sentence 7.4.10.6.(2) of Division B of the Regulation is amended by striking out “norminally” and substituting “nominally”.

105. The heading to Table 7.4.10.9. of Division B of the Regulation is revoked and the following substituted:

Maximum Permitted Hydraulic Load Drained to a Horizontal Storm Drainage Pipe

106. (1) Clause 7.5.2.1.(1)(e) of Division B of the Regulation is amended by striking out “Sentence 7.5.1.1.(3)” at the end and substituting “Clauses 7.5.1.1.(3)(a) to (c)”.

(2) Clause 7.5.2.1.(1)(j) of Division B of the Regulation is amended by striking out “Sentence 7.5.1.1.(3)” and substituting “Clauses 7.5.1.1.(3)(a) to (c)”.

107. (1) Sentence 7.5.4.5.(1) of Division B of the Regulation is amended by striking out “offset relief vent, relief vent or yoke vent” in the portion before Clause (a) and substituting “offset relief vent or yoke vent”.

(2) Clause 7.5.4.5.(1)(b) of Division B of the Regulation is amended by striking out “double sanitary T fitting, and” at the end and substituting “double fitting, in accordance with Table 7.2.4.5., and”.

108. Table 7.5.6.3. of Division B of the Regulation is amended by striking out the following row:

 

1

1.5

1/50

109. Table 7.5.8.4. of Division B of the Regulation is revoked and the following substituted:

Table 7.5.8.4.
Size and Developed Length of Stack Vents and Vent Stacks

Forming Part of Sentence 7.5.8.4.(1)

 

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Column 8

Column 9

Column 10

Column 11

Column 12

Column 13

Size of Soil or Waste Stack, in.

Total Hydraulic Load Being Vented, fixture units

Water Occupied Area

Size of Stack Vent or Vent Stack, in.

 

 

 

1 ½

2

3

4

5

6

8

10

12

 

 

 

Maximum Length of Stack Vent or Vent Stack, m

2

0.29

9

 

 

 

 

8

0.25

15

46

 

 

 

10

.29

9

30.5

 

 

 

2

12

0.25

9

23

61

 

 

20

.29

8

15

46

 

 

3

10

0.15

 

13

46

317

Not Limited

 

21

.20

 

10

33.5

247

 

 

53

.25

 

8

28.5

207

 

 

102

.29

 

7.5

26

189

 

4

43

0.15

Not Permitted

10.5

76

299

Not Limited

 

140

.20

8

61

229

 

 

320

.25

7

52

195

 

 

540

.29

6.5

46

177

 

5

190

0.15

Not Permitted

25

97.5

302

Not Limited

 

490

.20

29

76

232

 

 

940

.25

16

64

204

 

 

1 400

.29

15

58

180

 

6

500

0.15

Not Permitted

10

39.5

122

305

Not Limited

 

1 100

.20

8

30.5

94.5

238

 

 

2 000

.25

6.5

25.5

79

201

 

 

2 900

.29

6

23.5

73

183

 

8

1 800

0.15

Not Permitted

9.5

29

73

287

Not Limited

 

3 400

.20

7

22

58

219.5

 

 

5 600

.25

6

19

49

186

 

 

7 600

.29

5.5

17

43

70.5

 

10

4 000

0.15

Not Permitted

9.5

24

94.5

292.5

Not Limited

 

7 200

.20

7

18

73

225.5

 

 

11 000

.25

6

15.5

61

192

 

 

15 000

.29

5.5

14

55

174

 

12

7 300

0.15

Not Permitted

9.5

36.5

116

287

 

13 000

.20

7

28.5

91

219.5

 

20 000

.25

6

24

76

186

 

26 000

.29

5.5

22

70

152

15

15 000

0.15

Not Permitted

12

39.5

94.5

 

25 000

.20

9.5

29

73

 

38 000

.25

8

24.5

62

 

50 000

.29

7

22.5

55

110. Sentence 7.6.1.13.(2) of Division B of the Regulation is amended by striking out ““Installation Code for Solar Domestic Hot Water Systems”” at the end and substituting ““Installation of Packaged Solar Domestic Hot Water Systems””.

111. Sentence 7.6.2.4.(5) of Division B of the Regulation is amended by striking out “Except as permitted in Sentences (1) and (8)” at the beginning and substituting “Except as provided in Sentences (1) and (8) and Article 7.6.2.5.”.

112. Article 7.6.2.5. of Division B of the Regulation is revoked and the following substituted:

7.6.2.5. Backflow from Buildings with a Solar Domestic Hot Water System

(1) Except as permitted by Sentence (2) and as provided in Sentences (3) and (4), a potable water system shall be protected against backflow where the heat transfer loop of a solar domestic hot water system is directly connected to the potable water system.

(2) Where the heat transfer loop of the solar domestic hot water system consists of direct flow-through of potable water only, protection against backflow is not required.

(3) A potable water system that is directly connected to a solar domestic hot water system that serves a residential occupancy within the scope of Part 9, shall be provided with a backflow prevention device selected in accordance with CSA F379.1, “Packaged Solar Domestic Hot Water Systems (Liquid-to-Liquid Heat Transfer) for All-Season Use”.

(4) Where a solar domestic hot water system includes a single wall heat exchanger and contains only a relatively harmless heat transfer fluid as described in CSA F379.1, “Packaged Solar Domestic Hot Water Systems (Liquid-to-Liquid Heat Transfer) for All-Season Use”, the backflow prevention required in Sentence (1) is permitted to be a dual check valve backflow preventer conforming to CAN/CSA-B64.3, “Backflow Preventers, Dual Check Valve with Atmospheric Port Type (DCAP)”.

113. Table 7.6.3.1. of Division B of the Regulation is amended by striking out,

 

Bathroom group

 

 

 

 

and substituting,

 

Bathroom group

 

 

 

 

114. Sentences 7.6.4.2.(2) to (4) and Tables 7.6.4.2.A. and 7.6.4.2.B. of Division B of the Regulation are revoked and the following substituted:

(2) The flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.

Table 7.6.4.2.
Maximum Flush Cycles for Sanitary Fixtures

Forming Part of Sentence 7.6.4.2.(2)

 

Column 1

Column 2

Fixture

litres

Water Closet (Tank Type)

6

Water Closet (Direct Flush)

6

Urinal (Tank Type)

3.8(1)

Urinal (Direct Flush)

3.8(1)

Notes to Table 7.6.4.2.:

(1) Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time.

(3) Sentence (2) does not apply to a fixture located in an existing building where the chief building official is satisfied that compliance with the requirement is impracticable because of maintenance or operational difficulties.

115. (1) Sentence 7.6.5.2.(1) of Division B of the Regulation is amended by striking out “CAN/CSA-B125, “Plumbing Fittings”” at the end and substituting “ASME A112.18.1 / CAN/CSA-B125.1, “Plumbing Supply Fittings””.

(2) Sentence 7.6.5.2.(2) of Division B of the Regulation is amended by striking out “CAN/CSA-B125, “Plumbing Fittings”” at the end and substituting “CAN/CSA-B125.3, “Plumbing Fittings””.

116. (1) Sentence 8.1.3.1.(4) of Division B of the Regulation is amended by striking out “interceptor” and substituting “interceptor”.

(2) Sentence 8.1.3.1.(8) of Division B of the Regulation is amended by striking out “interceptor” and substituting “interceptor”.

117. Sentence 8.2.1.6.(2) of Division B of the Regulation is amended by striking out “Sentence 8.7.4.2.(9)” at the end and substituting “Sentence 8.7.4.2.(11)”.

118. Sentence 8.2.2.3.(8) of Division B of the Regulation is amended by striking out “1 200 mm” and substituting “1 000 mm”.

119. (1) Sentence 8.3.4.1.(1) of Division B of the Regulation is amended by striking out “privy-vault” in the portion before Clause (a) and substituting “privy vault”.

(2) Clause 8.3.4.1.(1)(c) of Division B of the Regulation is amended by striking out “privy-vault” and substituting “privy vault”.

120. The heading to Table 8.6.2.2.A. of Division B of the Regulation is amended by striking out “Forming Part of Sentence 8.6.2.2.(1), (2) and (5)” and substituting “Forming Part of Sentences 8.6.2.2.(1), (2) and (5)”.

121. (1) Clause 8.7.3.2.(1)(c) of Division B of the Regulation is amended by striking out “less than 300 mm” and substituting “less than 600 mm”.

(2) Clause 8.7.3.2.(1)(e) of Division B of the Regulation is amended by striking out “trench” and substituting “absorption trench”.

122. Sentence 8.7.5.3.(7) of Division B of the Regulation is amended by striking out “Clause 8.7.3.3.(1)(b)” and substituting “Clause 8.7.3.3.(1)(c)”.

123. Sentence 8.9.2.1.(1) of Division B of the Regulation is amended by striking out “The requirement” at the beginning and substituting “The requirements”.

124. Sentence 8.9.3.1.(1) of Division B of the Regulation is amended by striking out “The requirement” at the beginning and substituting “The requirements”.

125. Clause 9.1.1.9.(1)(b) of Division B of the Regulation is revoked and the following substituted:

(b) CSA A277, “Procedures for Factory Certification of Buildings”.

126. Subsection 9.1.1. of Division B of the Regulation is amended by adding the following Article:

9.1.1.10. Public Pools and Public Spas

(1) Public pools shall conform to the requirements of Section 3.11. and public spas shall conform to the requirements of Section 3.12.

127. Subsection 9.1.1. of Division B of the Regulation is amended by adding the following Article:

9.1.1.11. Shelf and Rack Storage Systems

(1) Shelf and rack storage systems shall conform to the requirements of Section 3.16.

128. (1) Sentence 9.3.1.1.(3) of Division B of the Regulation is amended by striking out “in Sentence (4)” and substituting “in Sentence (4), Subsection 9.15.4. and Section 9.40.”.

(2) Sentence 9.3.1.1.(4) of Division B of the Regulation is amended by striking out “2 storeys” in the portion before Clause (a) and substituting “2 storeys in building height”.

129. Sentence 9.3.1.3.(1) of Division B of the Regulation is amended by striking out “Clause 15.5” and substituting “Clause 4.1.1.6.”.

130. Table 9.3.1.7. of Division B of the Regulation is amended by striking out “course” wherever it appears and substituting in each case “coarse”.

131. Sentence 9.3.2.1.(1) of Division B of the Regulation is amended by striking out “(Interpretation Included)” at the end.

132. Sentence 9.3.2.9.(5) of Division B of the Regulation is amended by striking out “or” at the end of Clause (d), by adding “or” at the end of Clause (e) and by adding the following Clause:

(f) CSA O80.36, “Preservative Treatment of Wood Products for Light-Duty Above-Ground Residential Uses by Pressure Processes”.

133. Sentence 9.4.4.2.(1) of Division B of the Regulation is amended by striking out “lower allowable bearing pressure” and substituting “lower allowable bearing pressure”.

134. Article 9.7.1.7. of Division B of the Regulation is revoked and the following substituted:

9.7.1.7. Air Infiltration of Exterior Windows

(1) The air leakage rate of windows shall not exceed 1.65 m3/h per metre of crack length when evaluated in accordance with the CAN/CSA-A440.1, “User Selection Guide to CSA Standard CAN/CSA-A440-00 Windows”.

135. Sentence 9.8.6.2.(3) of Division B of the Regulation is amended by striking out the portion before Clause (a) and substituting the following:

(3) A landing may be omitted at the top of a stair serving a secondary entrance to a single dwelling unit, including an entrance from an attached garage, provided,

. . . . .

136. Clause 9.8.7.1.(1)(b) of Division B of the Regulation is amended by striking out “ramps” and substituting “curved ramps”.

137. (1) Sentence 9.8.8.2.(1) of Division B of the Regulation is amended by striking out “loads specified in” and substituting “specified loads prescribed in”.

(2) Sentence 9.8.8.2.(3) of Division B of the Regulation is amended by striking out “loads specified in” and substituting “specified loads prescribed in”.

(3) Table 9.8.8.2. of Division B of the Regulation is amended by striking out,

 

Location of Guard

Minimum Design Loads

and substituting,

 

Location of Guard

Minimum Specified Loads

138. Sentence 9.8.8.3.(5) of Division B of the Regulation is amended by striking out “a line” and substituting “from the top of the guard to a line”.

139. Sentence 9.8.9.6.(2) of Division B of the Regulation is amended by striking out “The finish for treads and landings of interior stairs” at the beginning and substituting “The finish for treads, landings and ramps”.

140. Clauses 9.9.6.3.(1)(b) and (c) of Division B of the Regulation are revoked and the following substituted:

(b) doors that open into or are located,

(i) within a public corridor, or

(ii) within another facility that provides access to exit from a suite.

141. Article 9.9.6.5. of Division B of the Regulation is revoked and the following substituted:

9.9.6.5. Direction of Door Swing

(1) Except as permitted by Sentence (2) and except for doors serving a single dwelling unit, exit doors that are required to swing shall swing in the direction of exit travel.

(2) An exit door need not swing in the direction of exit travel where it serves,

(a) a room, suite or floor area having an occupant load of not more than 60 persons, or

(b) as part of a means of egress from more than one floor area and the floor areas so served have a total occupant load of not more than 60 persons.

(3) Doors that open onto a corridor or other facility that provides access to exit from a room or suite having an occupant load of more than 60 persons shall swing on the vertical axis in the direction of exit travel.

(4) Doors that divide a corridor that is not wholly contained within a suite shall swing in the direction of exit travel.

(5) Where a pair of doors is installed in a corridor that provides access to exit in both directions, the doors shall,

(a) swing in opposite directions, with the door on the right hand side swinging in the direction of exit travel, or

(b) swing in both directions.

142. Sentence 9.9.9.2.(1) of Division B of the Regulation is amended by striking out “Sentence 9.9.7.2.(1)” and substituting “Sentence 9.9.7.3.(1)”.

143. Sentence 9.10.9.4.(4) of Division B of the Regulation is amended by striking out “Article 9.10.8.8.” and substituting “Article 9.10.8.9.”.

144. Sentence 9.10.12.4.(2) of Division B of the Regulation is amended by striking out “Sentence (1) and” in the part before Clause (a) and substituting “Sentence (1)”.

145. Sentence 9.10.13.1.(1) of Division B of the Regulation is amended by striking out “Chapters 2 to 14 of NFPA 80, “Fire Doors and Windows”” and substituting “NFPA 80, “Fire Doors and Other Opening Protectives””.

146. Sentence 9.10.13.2.(1) of Division B of the Regulation is amended by striking out ““CAN4-S113, “Wood Core Doors Meeting the Performance Required by CAN4-S104-77 for Twenty Minute Fire-Rated Closure Assemblies”” at the end and substituting “CAN/ULC-S113, “Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies””.

147. (1) Subclause 9.10.14.4.(1)(c)(ii) of Division B of the Regulation is amended by striking out “twice” at the beginning and substituting “half”.

(2) Sentence 9.10.14.4.(2) of Division B of the Regulation is amended by striking out “Openings” at the beginning and substituting “Except as provided in Sentence 9.10.14.6.(1), openings”.

148. Sentence 9.10.15.3.(1) of Division B of the Regulation is amended by striking out “Sentences 9.10.15.4.(2), (5) and (6)” and substituting “Sentences 9.10.15.4.(2) and (5)”.

149. (1) Clause 9.10.15.4.(1)(b) of Division B of the Regulation is amended by adding “as if the glazed openings were unprotected openings” after “Subsection 3.2.3.”.

(2) Sentence 9.10.15.4.(2) of Division B of the Regulation is revoked and the following substituted:

(2) Where the limits on the area of glazed openings are determined for individual portions of the exterior wall, as described in Subclause 9.10.15.2.(1)(b)(iii), the maximum aggregate area of glazed openings for any portion shall not exceed the values in the row of Table 9.10.15.4. for the total area of the entire exposing building face based on the limiting distance of the individual portion.

150. Clause 9.10.17.10.(1)(c) of Division B of the Regulation is amended by striking out “Clause 3.1.5.11.(2)(e)” at the end and substituting “Clause 3.1.5.12.(2)(e)”.

151. Clause 9.11.1.1.(1)(b) of Division B of the Regulation is revoked and the following substituted:

(b) ASTM E336, “Measurement of Airborne Sound Attenuation Between Rooms in Buildings”.

152. Table 9.12.2.2. of Division B of the Regulation is revoked and the following substituted:

Table 9.12.2.2.
Minimum Depths of Foundations

Forming Part of Sentence 9.12.2.2.(1)

 

Column 1

Column 2

Column 3

Column 4

Column 5

Type of Soil

Minimum Depth of Foundation Containing Heated Basement or Crawl Space(1)

Minimum Depth of Foundation Containing no Heated Space(2)

Good Soil Drainage

Poor Soil Drainage

Good Soil Drainage

Poor Soil Drainage

Rock

No limit

No limit

No limit

No limit

Coarse grained soils

No limit

No limit

No limit

Below the depth of frost penetration

Silt

No limit

No limit

Below the depth of frost penetration(3)

Below the depth of frost penetration

Clay or soils not clearly defined

1.2 m(3)

1.2 m

1.2 m but not less than the depth of frost penetration(3)

1.2 m but not less than the depth of frost penetration

Notes to Table 9.12.2.2.:

(1)Foundation not insulated to reduce heat loss through the footings.

(2) Including foundations containing heated space insulated to reduce heat loss through the footings.

(3) Good soil drainage to not less than the depth of frost penetration.

153. (1) Sentence 9.13.2.4.(1) of Division B of the Regulation is amended by striking out “that are” in the portion before Clause (a).

(2) Sentence 9.13.2.4.(3) of Division B of the Regulation is revoked and the following substituted:

(3) The surface of insulating concrete form walls to be dampproofed shall be repaired and free of projections and depressions that could be detrimental to the performance of the membrane to be applied.

154. Clause 9.14.3.1.(1)(h) of Division B of the Regulation is revoked and the following substituted:

(h) BNQ 3624-115, “Polyethylene (PE) Pipe Fittings – Flexible Pipes for Drainage – Characteristics and Test Methods”.

155. Subclause 9.15.1.1.(1)(c) (i) of Division B of the Regulation is amended by striking out “100 kPa” and substituting “75 kPa”.

156. Sentence 9.15.3.2.(2) of Division B of the Regulation is amended by striking out “Granular fill” at the beginning and substituting “Granular fill”.

157. (1) Subclause 9.15.3.3.(1)(a)(i) of Division B of the Regulation is amended by striking out “concrete form foundation walls” at the end and substituting “concrete form walls”.

(2) Subclause 9.15.3.3.(1)(a)(ii) of Division B of the Regulation is amended by striking out “concrete form foundation walls” and substituting “concrete form walls”.

158. Clause 9.15.3.4.(2)(b) of Division B of the Regulation is amended by striking out,

∑ sjs =   the sum of the supported joist lengths on each storey whose load is transferred to the footing, and

and substituting,

∑ sjs =   the sum of the supported joist spans on each storey whose load is transferred to the footing, and

159. (1) Table 9.15.4.5.A. of Division B of the Regulation is amended by striking out “Maximum Vertical Reinforcement” in the heading under Columns 2, 3 and 4 and substituting “Minimum Vertical Reinforcement”.

(2) Table 9.15.4.5.B. of Division B of the Regulation is amended by striking out “Maximum Vertical Reinforcement” in the heading under Columns 2, 3 and 4 and substituting “Minimum Vertical Reinforcement”.

(3) Table 9.15.4.5.C. of Division B of the Regulation is amended by striking out “Maximum Vertical Reinforcement” in the heading under Columns 2, 3 and 4 and substituting “Minimum Vertical Reinforcement”.

160. Clause 9.17.1.1.(1)(b) of Division B of the Regulation is amended by adding “and” at the end of Subclause (ii), by striking out “and” at the end of Subclause (iii) and substituting “or” and by revoking Subclause (iv).

161. Clause 9.19.1.3.(2)(b) of Division B of the Regulation is amended by striking out “vertically above” and substituting “above”.

162. Sentence 9.19.2.1.(2) of Division B of the Regulation is revoked and the following substituted:

(2) The hatch required in Sentence (1) shall be not less than 550 mm by 900 mm except that, where the hatch serves a single dwelling unit, the hatch may be reduced to,

(a) 0.32 m2 in area with no dimension less than 545 mm, or

(b) 500 mm by 700 mm.

163. (1) Sentence 9.20.1.2.(1) of Division B of the Regulation is amended by striking out “Sa(2.0)” and substituting “Sa(0.2)”.

(2) Sentence 9.20.1.2.(2) of Division B of the Regulation is amended by striking out “Sa(2.0)” and substituting “Sa(0.2)”.

164. Table 9.20.5.2.A. of Division B of the Regulation is amended by striking out the heading “Exterior Angles” under Columns 2 and 3 and substituting “Exterior Angles, mm” and by striking out the heading “Interior Angles” under Columns 5 to 11 and substituting “Interior Angles, mm”.

165. Sentence 9.20.6.2.(2) of Division B of the Regulation is amended by striking out “nor greater than” and substituting “and not greater than”.

166. Clause 9.20.7.3.(1)(a) of Division B of the Regulation is amended by striking out “measured from centre to centre”.

167. Sentence 9.20.11.1.(1) of Division B of the Regulation is amended by striking out “grade” and substituting “grade”.

168. Sentence 9.20.11.2.(2) of Division B of the Regulation is amended by striking out “imbedded” and substituting “embedded”.

169. The heading to Article 9.20.17.3. of Division B of the Regulation is revoked and the following substituted:

9.20.17.3. Openings in Non-Loadbearing Flat Insulating Concrete Form Walls

170. Sentence 9.21.2.1.(3) of Division B of the Regulation is amended by striking out “solid-fuel burning” wherever it appears and substituting in each case “solid fuel-burning”.

171. (1) Sentence 9.22.9.3.(1) of Division B of the Regulation is amended by striking out “solid fuel burning” and substituting “solid fuel-burning”.

(2) Sentence 9.22.9.3.(2) of Division B of the Regulation is amended by striking out “solid fuel burning” and substituting “solid fuel-burning”.

172. Clause 9.22.9.4.(1)(a) of Division B of the Regulation is amended by striking out “more than” and substituting “not less than”.

173. The heading to Article 9.22.10.1. of Division B of the Regulation is revoked and the following substituted:

9.22.10.1. Appliance Standard

174. Sentence 9.23.2.5.(1) of Division B of the Regulation is amended by striking out “above grade” at the end and substituting “above the ground”.

175. Sentence 9.23.10.4.(1) of Division B of the Regulation is amended by striking out “storey” and substituting “storey”.

176. Sentence 9.23.15.7.(2) of Division B of the Regulation is amended by striking out “Table 9.23.16.7.B.” at the end and substituting “Table 9.23.15.7.B.”.

177. Table 9.23.16.2.A. of Division B of the Regulation is amended by striking out,

 

Gypsum Sheathing

9.5

12.7

CAN/CSA-A82.27-M

ASTM C79 / C79M

ASTM C1177 / C1177M

ASTM C1396 / C1396M

and substituting,

 

Gypsum Sheathing

9.5

12.7

CAN/CSA-A82.27-M

ASTM C1177 / C1177M

ASTM C1396 / C1396M

178. Sentence 9.23.16.6.(1) of Division B of the Regulation is amended by striking out “Subsection 9.23.17.” at the end and substituting “Articles 9.27.3.2. to 9.27.3.6.”.

179. (1) Clause 9.25.1.2.(4)(b) of Division B of the Regulation is revoked and the following substituted:

(b) the intended use of the interior space will result in an indoor relative humidity above 35% over the heating season and the ventilating and air-conditioning system does not have the capacity to reduce the relative humidity to 35% or less over that period.

(2) Sentence 9.25.1.2.(7) of Division B of the Regulation is revoked and the following substituted:

(7) For walls, the air space described in Clause (2)(c) shall be drained and ventilated and be not less than 10 mm deep behind the cladding, over the full height and width of the wall.

180. Subsection 9.25.3. of Division B of the Regulation is revoked and the following substituted:

9.25.3. Air Barrier Systems

9.25.3.1. Required Barrier to Air Leakage

(1) Wall, ceiling and floor assemblies that separate conditioned spaces from unconditioned spaces shall be constructed so as to include an air barrier system that will provide a continuous barrier to air leakage,

(a) from the interior of the building into wall, floor, attic or roof spaces sufficient to prevent excessive moisture condensation in such spaces during the heating season, and

(b) from the exterior inward sufficient to prevent moisture condensation on the room side during the heating season.

(2) The continuity of the air barrier system shall extend throughout the basement.

9.25.3.2. Air Barrier System Properties

(1) Sheet and panel type materials intended to provide the principal resistance to air leakage shall have an air leakage characteristic not greater than 0.02 L/(s∙m2) measured at an air pressure differential of 75 Pa.

(2) Where polyethylene sheet is used to provide the air-tightness in the air barrier system, it shall conform to CAN/CGSB-51.34-M, “Vapour Barrier, Polyethylene Sheet for Use in Building Construction”.

9.25.3.3. Continuity of the Air Barrier System

(1) Where the air barrier system consists of an air-impermeable panel-type material, all joints shall be sealed to prevent air leakage.

(2) Where the air barrier system consists of flexible sheet material, all joints shall be,

(a) sealed with compatible material such as tape or flexible sealant, or

(b) except as required by Sentence (3), lapped not less than 100 mm and clamped, such as between framing members, furring or blocking and rigid panels.

(3) Where an air barrier system consisting of flexible sheet material is installed at locations where it is not supported by an interior finish, such as a behind a bath tub, shower enclosure or fireplace, the continuity of the air barrier shall be maintained by sealing its joints.

(4) Where an interior wall meets an exterior wall, ceiling, floor or roof required to be provided with an air barrier protection, the air barrier system shall extend across the intersection and shall be sealed in accordance with Sentences (1) and (2).

(5) Where an interior wall projects through a ceiling or extends to become an exterior wall, spaces in the wall shall be blocked to provide continuity across those spaces with the air barrier system in the abutting walls or ceiling by,

(a) sealing each air barrier to the blocking, or

(b) wrapping each air barrier around the transition and sealing in accordance with Sentences (1) and (2).

(6) Where an interior floor projects through an exterior wall or extends to become an exterior floor, continuity of the air barrier system shall be maintained from the abutting walls across the floor assembly.

(7) Where an interior floor projects through an exterior wall to become an exterior floor,

(a) the air barrier of the wall under the floor shall be continuous with or sealed to the subfloor or the air barrier on the underside of the floor,

(b) the air barrier of the wall above the floor shall be continuous with or sealed to the subfloor or the air barrier on the top of the floor, and

(c) the spaces between floor joists shall be blocked and sealed.

(8) Where a header wrap is used as an air barrier, it shall be sealed or lapped to the wall air barrier above and below in accordance with Sentences (1) and (2).

(9) Penetrations of the air barrier system, such as those created by the installation of electrical wiring, electrical boxes, piping or ductwork, shall be sealed with compatible material such as tape or caulking to maintain the integrity of the air barrier system over the entire surface.

(10) Penetrations of the air barrier system, such as those created by the installation of doors, windows and other fenestration shall be sealed to maintain the integrity of the air barrier system over the entire surface.

(11) Where an interior air barrier is penetrated by doors, windows and other fenestration, the air barrier shall be sealed to the door frame or window frame with,

(a) compatible tape, or

(b) spray foam insulation.

(12) Where an exterior air barrier is penetrated by doors, windows and other fenestration, the air barrier shall be sealed to the door frame or window frame with,

(a) compatible flexible flashing material,

(b) caulking, or

(c) spray foam insulation.

(13) An access hatch installed through an assembly constructed with an air barrier system shall be weatherstripped around the perimeter to prevent air leakage.

(14) Clearances between chimneys or gas vents and the surrounding construction that would permit air leakage from within the building into a wall or attic or roof space shall be sealed by noncombustible material to prevent such leakage and shall be sealed to the air barrier with tape or another compatible material, and to the vent with high temperature caulking in accordance with the manufacturer’s installation instructions.

(15) Where the foundation wall and floor slab are used as an air barrier, they shall be caulked at all joints, intersections and penetrations.

(16) Sump pit covers shall be sealed.

9.25.3.4. Vapour Barriers Used as Air Barriers

(1) A vapour barrier used as an air barrier shall comply with the requirements of this Subsection.

181. (1) Sentence 9.25.4.2.(1) of Division B of the Regulation is amended by striking out “Vapour barriers” at the beginning and substituting “Except as provided in Sentences (2) and (3), vapour barriers”.

(2) Clause 9.25.4.2.(3)(b) of Division B of the Regulation is amended by striking out “60% over that period” at the end and substituting “60% or less over that period”.

182. (1) Clause 9.26.2.1.(1)(h) of Division B of the Regulation is revoked and the following substituted:

(h) CAN/CGSB-37.54, “Polyvinyl Chloride Roofing and Waterproofing Membrane”,

(2) Clauses 9.26.2.1.(1)(l), (m) and (n) of Division B of the Regulation are revoked and the following substituted:

(l) CSA A123.1 / A123.5, “Asphalt Shingles Made from Organic Felt and Surfaced with Mineral Granules / Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules”,

(m) CAN/CSA-A123.2, “Asphalt Coated Roofing Sheets”,

(n) CSA A123.3, “Asphalt Saturated Organic Roofing Felt”,

(3) Clauses 9.26.2.1.(1)(p) and (q) of Division B of the Regulation are revoked and the following substituted:

(p) Reserved

(q) CSA A123.17, “Asphalt Glass Felt Used in Roofing and Waterproofing”,

183. Clause 9.26.3.1.(4)(b) of Division B of the Regulation is amended by striking out “by other than” and substituting “by more than”.

184. Clauses 9.29.5.2.(1)(b) to (j) of Division B of the Regulation are revoked and the following substituted:

(b) Reserved

(c) Reserved

(d) Reserved

(e) Reserved

(f) Reserved

(g) Reserved

(h) Reserved

(i) ASTM C1178 / C1178M, “Coated Glass Mat Water-Resistant Gypsum Backing Panel”, or

(j) Reserved

185. (1) Table 9.29.5.3. of Division B of the Regulation is amended by striking out,

 

Gypsum board conforming to Clauses 9.29.5.2.(1)(a) to (i) and (k)

and substituting,

 

Gypsum board conforming to Sentence 9.29.5.2.(1) (except Sections 9 and 12 of ASTM C1396 / C1396M)

(2) Table 9.29.5.3. of Division B of the Regulation is amended by striking out,

 

Gypsum board conforming to Clause 9.29.5.2.(1)(j)

and substituting,

 

Gypsum board conforming to Clause 9.29.5.2.(1)(k) (only Section 12 of ASTM C1396 / C1396M)

186. Sentence 9.29.5.9.(5) of Division B of the Regulation is amended by striking out “based on Supplementary Standard SB-3” and substituting “based on Table 1 of Supplementary Standard SB-3”.

187. Sentence 9.30.6.4.(3) of Division B of the Regulation is amended by striking out “imbedded” and substituting “embedded”.

188. Sentence 9.32.3.3.(1) of Division B of the Regulation is revoked and the following substituted:

9.32.3.3. Total Ventilation Capacity

(1) The minimum total ventilation capacity of the ventilation system required in Clause 9.32.3.2.(1)(b) shall be the greater of,

(a) the sum of the individual room capacities given in Table 9.32.3.3., or

(b) 0.3 air changes per hour based on the conditioned volume of the dwelling unit.

189. (1) Table 9.32.3.4.A. of Division B of the Regulation is revoked and the following substituted:

Table 9.32.3.4.A.
Principal Exhaust Fan Capacity

Forming Part of Sentence 9.32.3.4.(1)

 

Column 1

Column 2

Number of Bedrooms in Dwelling Unit

Capacity, L/s

1

15

2

22.5

3

30

4

37.5

5

45

More than 5

System must comply with Sentence 6.2.1.1.(1)

(2) Table 9.32.3.4.B. of Division B of the Regulation is revoked and the following substituted:

Table 9.32.3.4.B.
Principal Exhaust Duct Size

Forming Part of Sentence 9.32.3.4.(9)

 

Column 1

Column 2

Column 3

Column 4

Column 5

Number of Bedrooms in Dwelling Unit

Minimum Exhaust Duct Diameter

Ducts Connected to Inlet and Outlet of Principal Exhaust Fan

Ducts Connected to One Side Only of Principal Exhaust Fan

Smooth Duct, mm

Flexible Duct, mm

Smooth Duct, mm

Flexible Duct, mm

1

100

125

100

125

2

125

150

125

150

3

125

150

150

175

4

150

175

150

175

5

150

175

150

175

More than 5

Part 6 design

Part 6 design

Part 6 design

Part 6 design

190. Sentence 9.32.3.5.(7) of Division B of the Regulation is amended by striking out “Sentence 9.32.3.4.(5)” at the end and substituting “Sentence 9.32.3.4.(4)”.

191. (1) Sentence 9.32.3.7.(8) of Division B of the Regulation is amended by striking out “more than 4 bedrooms” and substituting “more than 5 bedrooms”.

(2) Table 9.32.3.7.A. of Division B of the Regulation is revoked and the following substituted:

Table 9.32.3.7.A.
Minimum Outdoor Air Supply and Main Trunk Duct Sizes

Forming Part of Sentence 9.32.3.7.(5)

 

Column 1

Column 2

Number of Bedrooms in Dwelling Unit

Minimum Outdoor Air Supply and Main Distribution Trunk Duct Diameter, mm

1

150

2

150

3

175

4

175

5

175

More than 5

System must comply with Sentence 6.2.1.1.(1)

(3) Table 9.32.3.7.B. of Division B of the Regulation is revoked and the following substituted:

Table 9.32.3.7.B.
Minimum Branch Supply Duct Sizes

Forming Part of Sentence 9.32.3.7.(7)

 

Column 1

Column 2

Column 3

Room, Space or Storey Served

Minimum Branch Supply Duct Diameter, mm

1 and 2 Bedroom Dwelling Units

3, 4 and 5 Bedroom Dwelling Units

Master bedroom

100

100

Other bedrooms

75

75

Storey with no bedrooms or living area

75

100

192. (1) Sentence 9.32.3.10.(4) of Division B of the Regulation is amended by striking out “supply duct” and substituting “duct”.

(2) The heading to Table 9.32.3.10.A. of Division B of the Regulation is revoked and the following substituted:

Table 9.32.3.10.A.
Insulation of Ducts Carrying Outdoor Air

Forming Part of Sentence 9.32.3.10.(4)

193. (1) Clause 9.33.4.3.(1)(a) of Division B of the Regulation is amended by adding “except as permitted in Sentence (2)” at the beginning.

(2) Article 9.33.4.3. of Division B of the Regulation is amended by adding the following Sentence:

(2) Where the building is not supplied with electrical power, carbon monoxide detectors are permitted to be battery operated.

194. Sentence 9.35.3.3.(1) of Division B of the Regulation is amended by striking out “50 m²” and substituting “55 m²”.

195. Sentence 9.36.2.1.(3) of Division B of the Regulation is amended by striking out “vapour barrier, air-barrier” and substituting “vapour barrier, air barrier”.

196. The heading to Table A-12 of Division B of the Regulation is amended by striking out “Forming Part of Sentence 9.23.4.2.(4)” and substituting “Forming Part of Sentences 9.23.4.2.(4), 9.23.12.3.(1) and 9.37.3.1.(1)”.

197. (1) The heading to Table A-13 of Division B of the Regulation is amended by striking out “Forming Part of Sentences 9.23.12.3.(1) and (3)” and substituting “Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1)”.

(2) Table A-13 of Division B of the Regulation is amended,

(a) by striking out “Roof, ceiling and 1 storey” in Column 1 and substituting “Roof, ceiling and 1 storey”,

(b) by striking out “Roof, ceiling and 2 storeys” in Column 1 and substituting “Roof, ceiling and 2 storeys”, and

(c) by striking out “Roof, ceiling and 3 storeys” in Column 1 and substituting “Roof, ceiling and 3 storeys”.

198. The heading to Table A-14 of Division B of the Regulation is amended by striking out “Forming Part of Sentences 9.23.12.3.(1) and (3)” and substituting “Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1)”.

199. The heading to Table A-15 of Division B of the Regulation is amended by striking out “Forming Part of Sentences 9.23.12.3.(1) and (3)” and substituting “Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1)”.

200. The heading to Table A-16 of Division B of the Regulation is amended by striking out “Forming Part of Sentences 9.23.12.3.(1) and (3)” and substituting “Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1)”.

201. (1) Table A-20 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-20 of Division B of the Regulation is amended by adding the following:

Notes to Table A-20:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

202. (1) Table A-21 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-21 of Division B of the Regulation is amended by adding the following:

Notes to Table A-21:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

203. (1) Table A-22 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-22 of Division B of the Regulation is amended by adding the following:

Notes to Table A-22:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

204. (1) Table A-23 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-23 of Division B of the Regulation is amended by adding the following:

Notes to Table A-23:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

205. (1) Table A-24 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-24 of Division B of the Regulation is amended by adding the following:

Notes to Table A-24:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

206. (1) Table A-25 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-25 of Division B of the Regulation is amended by adding the following:

Notes to Table A-25:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

207. (1) Table A-26 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-26 of Division B of the Regulation is amended by adding the following:

Notes to Table A-26:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

208. (1) Table A-27 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-27 of Division B of the Regulation is amended by adding the following:

Notes to Table A-27:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

209. (1) Table A-28 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-28 of Division B of the Regulation is amended by adding the following:

Notes to Table A-28:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

210. (1) Table A-29 of Division B of the Regulation is amended by striking out,

 

Supported Roof Length, m

2.4

3.6

4.8

6.0

Supported Floor Length, m

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

and substituting,

 

Supported Roof Length, m(1)

2.4

3.6

4.8

6.0

Supported Floor Length, m(2)

2.4

3.6

2.4

3.6

2.4

3.6

2.4

3.6

(2) Table A-29 of Division B of the Regulation is amended by adding the following:

Notes to Table A-29:

(1) Supported roof length means half the sum of the roof framing spans on both sides of the beam.

(2) Supported floor length means half the sum of the floor framing spans on both sides of the beam.

211. (1) Sentence 10.4.1.1.(1) of Division B of the Regulation is amended by striking out “Part 3, 4, 5, 6 or 7” in the portion before Clause (a) and substituting “Part 3, 4, 6 or 8”.

(2) Sentence 10.4.1.1.(2) of Division B of the Regulation is amended by striking out “Part 9” and substituting “Part 9 or 12”.

212. Sentence 11.3.3.1.(1) of Division B of the Regulation is amended by striking out “fire separations” and substituting “fire separations”.

213. Sentence 11.4.2.2.(3) of Division B of the Regulation is amended by striking out “exit capacity as required under Article 3.4.3.4.” at the end and substituting “exit capacity as required under Article 3.4.3.2.”.

214. (1) Sentence 11.4.2.3.(2) of Division B of the Regulation is amended by striking out “Clauses (1)(b) to (e)” and substituting “Clauses (1)(b) to (f)”.

(2) Sentence 11.4.2.3.(6) of Division B of the Regulation, as made by subsection 12 (2) of Ontario Regulation 205/08, is amended by striking out “Sentence 3.3.4.4.(5)” at the end and substituting “Sentence 3.3.4.4.(9)”.

215. Table 11.4.3.3. of Division B of the Regulation is amended by striking out “Compliance Alternative” in the heading under Column 3 and substituting “Compliance Alternative”.

216. Sentence 11.4.3.4.(2) of Division B of the Regulation is amended by striking out “Articles 9.5.1.1. to 9.5.1.5, Articles 9.5.3.1. to 9.5.10.1” and substituting “Subsections 9.5.1. and 9.5.3. to 9.5.10.”.

217. (1) Sentence 11.5.1.1.(1) of Division B of the Regulation is amended by striking out “Part 3, 4, 5, 6, 7 or 8” in the portion before Clause (a) and substituting “Part 3, 4, 6 or 8”.

(2) Sentence 11.5.1.1.(2) of Division B of the Regulation is amended by striking out “Part 9” and substituting “Part 9 or 12”.

(3) Table 11.5.1.1.A. of Division B of the Regulation is amended by striking out,

 

A20

3.2.5.5.; 3.2.5.6.; 3.2.5.4.

Existing acceptable provided the building is sprinklered.

and substituting,

 

A20

3.2.5.4.; 3.2.5.5.; 3.2.5.6.

Existing acceptable provided the building is sprinklered.

(4) Table 11.5.1.1.C. of Division B of the Regulation is amended by striking out,

 

C61

3.4.7.2.

Combustible fire escapes which are protected from fire in accordance with Sentence 3.2.3.14.(2) are permitted or may be reconstructed or recreated (as in the case of a heritage building).

and substituting,

 

C61

3.4.7.2.

Combustible fire escapes which are protected from fire in accordance with Sentence 3.2.3.13.(2) are permitted or may be reconstructed or recreated (as in the case of a heritage building).

218. Sentence 12.2.1.1.(3) of Division B of the Regulation is amended by striking out “or” at the end of Clause (b), by adding “or” at the end of Clause (c) and by adding the following Clause:

(d) conform to Supplementary Standard SB-12.

219. Sentence 12.2.1.2.(3) of Division B of the Regulation is revoked and the following substituted:

(3) The energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall,

(a) meet the performance level that is equal to a rating of 80 or more when evaluated in accordance with NRCan, “EnerGuide for New Houses: Administrative and Technical Procedures”, or

(b) conform to Supplementary Standard SB-12.

220. The title to Division C and the heading to Part 1 of Division C of the Regulation are revoked and the following substituted:

DIVISION c
Administrative provisions

Part 1
General

221. Sentence 1.2.1.1.(9) of Division C of the Regulation is amended by striking out “Sentence 3.16.1.6.(7)” and substituting “Sentence 3.16.1.7.(7)”.

222. (1) Sentence 1.3.1.3.(1) of Division C of the Regulation is revoked and the following substituted:

(1) Subject to Sentences (2) and (3) and unless the circumstances set out in Sentence (6) exist, if an application for a permit under subsection 8 (1) of the Act that meets the requirements of Sentence (5) is submitted to a chief building official on or after the day subsection 2 (2) of Schedule 21 to the Good Government Act, 2009 comes into force, the chief building official shall, within the time period set out in Column 3 of Table 1.3.1.3. corresponding to the class of building described in Column 2 of Table 1.3.1.3. for which the application is made,

(a) issue the permit, or

(b) refuse to issue the permit and provide in writing all of the reasons for the refusal.

(2) Sentences 1.3.1.3.(5), (6) and (7) of Division C of the Regulation are revoked and the following substituted:

(5) The requirements that an application for a permit under subsection 8 (1) of the Act must meet for the purposes of Sentence (1) are,

(a) that the application is made in the form described in Sentence 1.3.1.2.(2),

(b) that the applicant for the permit is a person described in Clause 1.3.1.2.(1)(a) or (b),

(c) that all applicable fields on the application form and required schedules are completed,

(d) that all required schedules are submitted with the application,

(e) that payment is made of all fees that are required, under the applicable by-law, resolution or regulation made under clause 7 (1) (c) of the Act, to be paid when the application is made, and

(f) that the applicant has declared in writing that,

(i) the application meets all the requirements set out in Clauses (a) to (e),

(ii) the application is accompanied by the plans and specifications prescribed by the applicable by-law, resolution or regulation made under clause 7 (1) (b) of the Act,

(iii) the application is accompanied by the information and documents prescribed by the applicable by-law, resolution or regulation made under clause 7 (1) (b) of the Act which enable the chief building official to determine whether the proposed building, construction or demolition will contravene any applicable law, and

(iv) the proposed building, construction or demolition will not contravene any applicable law.

(6) The chief building official is not required to make a decision within the time period required by Sentence (1) with respect to an application that meets the requirements of Sentence (5) if the chief building official,

(a) determines that,

(i) the application is not accompanied by the plans, specifications, information and documents referred to in Subclauses (5)(f)(ii) and (iii), or

(ii) the proposed building, construction or demolition will contravene any applicable law, and

(b) advises the applicant of his or her determination and provides in writing the reasons for the determination within two days.

(7) Subject to Sentences (8) and (9), the time period described in Sentences (1) to (3) and in Clause (6)(b) shall begin on the day following the day on which an application that meets the requirements of Sentence (5) is submitted to the chief building official.

(7.1) The time periods described in Column 3 of Table 1.3.1.3. and in Clause (6)(b) shall not include Saturdays, holidays and all other days when the offices of the principal authority are not open for the transaction of business with the public.

(3) Sentence 1.3.1.3.(9) of Division C of the Regulation is revoked and the following substituted:

(9) The time period described in Sentences (1) to (3) for an application referred to in Clause (8)(a) shall begin on the day following the later of,

(a) the day on which an application that meets the requirements of Sentence (5) is submitted to the chief building official, and

(b) the day on which a permit for the construction of the sewage system referred to in Clause (8)(b) is issued.

(10) This Article, as it read immediately before subsection 2 (2) of Schedule 21 to the Good Government Act, 2009 comes into force, continues to apply to an application for a permit under subsection 8 (1) of the Act that is submitted to a chief building official before that day.

(4) Table 1.3.1.3. of Division C of the Regulation is amended by striking out,

 

1

(a) A detached house, semi-detached house, townhouse, or row house where no dwelling unit is located above another dwelling unit.

10 days

 

(b) A detached structure that serves a building described in Clause (a) and does not exceed 50 m2 in building area.

 

 

(c) A tent to which Section 3.14. of Division B applies.

 

 

(d) A sign to which Section 3.15. of Division B applies.

 

and substituting,

 

1

(a) A detached house, semi-detached house, townhouse, or row house where no dwelling unit is located above another dwelling unit.

10 days

 

(b) A detached structure that serves a building described in Clause (a) and does not exceed 55 m2 in building area.

 

 

(c) A tent to which Section 3.14. of Division B applies.

 

 

(d) A sign to which Section 3.15. of Division B applies.

 

223. Subsection 1.3.1. of Division C of the Regulation is amended by adding the following Article:

1.3.1.6. Information to be given to Tarion Warranty Corporation

(1) This Article prescribes, for the purposes of subsection 8 (8.1) of the Act, the information relating to permits issued under section 8 of the Act and the applications for those permits that the chief building official is required to give to Tarion Warranty Corporation and the time within which the information is required to be given.

(2) The chief building official shall give the following information to Tarion Warranty Corporation with respect to permits issued under section 8 of the Act on or after the day subsection 2 (3) of Schedule 21 to the Good Government Act, 2009 comes into force in respect of the construction of buildings described in Sentence (4),

(a) the dates the permits are issued and the numbers or other identifying symbols for the permits, and

(b) the information contained in the application forms submitted in respect of the permits, other than the information contained in the schedules or other attachments to the application forms.

(3) Despite Sentence (2), the chief building official is not required to give to Tarion Warranty Corporation information which relates to the extension or material alteration or repair of an existing building.

(4) The buildings referred to in Sentence (2) are any building whose proposed use is classified as a Group C major occupancy and which is not a boarding, lodging or rooming house or a building containing a hotel.

(5) The chief building official shall give the information described in Sentence (2) within 45 days after the day on which the permits to which the information relates are issued.

(6) The time period described in Sentence (5) shall not include Saturdays, holidays and all other days when the offices of the principal authority are not open for the transaction of business with the public.

224. The heading to Subsection 1.3.3. of Division C of the Regulation is revoked and the following substituted:

1.3.3. Occupancy of Buildings

225. (1) The heading to Article 1.3.3.1. of Division C of the Regulation is revoked and the following substituted:

1.3.3.1. Occupancy Permit — General

(2) Article 1.3.3.1. of Division C of the Regulation is amended by adding the following Sentence:

(1.1) Sentence (1) does not apply in respect of the occupancy of a building to which Article 1.3.3.4. applies.

226. Article 1.3.3.2. of Division C of the Regulation is amended by adding the following Sentence:

(2) Sentence (1) does not apply in respect of the occupancy of a building to which Article 1.3.3.4. applies.

227. Sentence 1.3.3.3.(1) of Division C of the Regulation is amended by striking out “this Subsection” and substituting “Article 1.3.3.1. or 1.3.3.2.”.

228. Subsection 1.3.3. of Division C of the Regulation is amended by adding the following Article:

1.3.3.4. Occupancy Permit — Certain Buildings of Residential Occupancy

(1) No person shall occupy or permit to be occupied a building described in Sentence (4), or part of it, unless the chief building official or a person designated by the chief building official has issued a permit authorizing occupation of the building or part of it in accordance with Sentence (5).

(2) This Article applies in respect of the occupancy of a building described in Sentence (4) if a permit for the construction of the building has been applied for after December 31, 2011.

(3) This Article does not apply in respect of the occupancy of an existing building, or part of it, that has been subject to extension or material alteration or repair.

(4) A building referred to in Sentence (1) is a building intended for residential occupancy that,

(a) is of three or fewer storeys in building height and has a building area not exceeding 600 m²,

(b) has no accommodation for tourists,

(c) does not have a dwelling unit above another dwelling unit, and

(d) does not have any dwelling units sharing a common means of egress.

(5) The chief building official or a person designated by the chief building official shall issue a permit authorizing occupation of a building described in Sentence (4), where,

(a) the structure of the building with respect to the dwelling unit to be occupied is substantially complete and ready to be used for its intended purpose,

(b) the building envelope, including, but not limited to, cladding, roofing, windows, doors, assemblies requiring fire-resistance ratings, closures, insulation, vapour barriers and air barriers, with respect to the dwelling unit to be occupied, is substantially complete,

(c) the walls enclosing the dwelling unit to be occupied conform to Sentence 9.25.2.3.(7) of Division B,

(d) site grading with respect to the building is substantially complete,

(e) required electrical supply is provided for the dwelling unit to be occupied,

(f) required fire fighting access routes to the building have been provided and are accessible,

(g) the following building components and systems are complete and operational for the dwelling unit to be occupied:

(i) required exits, floor access and egress systems, handrails, guards, smoke alarms, carbon monoxide detectors and fire separations, including, but not limited to, fire stopping,

(ii) required exhaust fume barriers and self-closing devices on doors between an attached or built-in garage and the dwelling unit, and

(iii) water supply, sewage disposal, lighting and heating systems,

(h) the following building components and systems are complete, operational and tested for the dwelling unit to be occupied:

(i) water system,

(ii) building drain and building sewer, and

(iii) drainage system and venting system,

(i) required plumbing fixtures in the dwelling unit to be occupied are substantially complete and operational, and

(j) where applicable, the building conforms to Article 9.1.1.7. of Division B with respect to the dwelling unit to be occupied.

(6) Where a registered code agency has been appointed to perform the functions described in clause 4.1 (4) (b) or (c) of the Act in respect of the construction of a building described in Sentence (4), the chief building official or a person designated by the chief building official shall issue the permit referred to in Sentence (5) after receipt of a certificate for the occupancy of a building described in Sentence 1.3.3.4.(4) of Division C issued by the registered code agency in respect of the building.

229. (1) Clause 1.3.5.1.(2)(e) of Division C of the Regulation is revoked and the following substituted:

(e) substantial completion of insulation and vapour barriers,

(e.1) substantial completion of air barrier systems,

(2) Sentence 1.3.5.1.(2) of Division C of the Regulation is amended by striking out “and” at the end of Clause (m), by adding “and” at the end of Clause (n) and by adding the following Clause:

(o) completion of construction and installation of components required to permit the issue of an occupancy permit under Sentence 1.3.3.4.(5).

230. Sentence 1.3.5.2.(1) of Division C of the Regulation is amended by striking out “and” at the end of Clause (h), by adding “and” at the end of Clause (i) and by adding the following Clause:

(j) completion of a building for which an occupancy permit is required under Article 1.3.3.4.

231. Sentence 3.1.6.1.(1) of Division C of the Regulation is amended by striking out “3.1.4.1.(1)(c)” in the portion before Clause (a) and substituting “3.1.4.1.(1)(b)”.

232. Sentence 3.1.7.1.(1) of Division C of the Regulation is amended by striking out “3.1.4.1.(1)(c)” and substituting “3.1.4.1.(1)(b)”.

233. Clause 3.4.3.3.(3)(f) of Division C of the Regulation is amended by striking out “Sentences 3.7.5.3.(1) and (2)” at the end and substituting “Sentences 3.7.4.3.(1) and (2)”.

234. The heading to Table 3.5.2.2. of Division C of the Regulation is amended by striking out “Qualifications” and substituting “Qualifications for”.

235. Article 3.7.4.3. of Division C of the Regulation is amended by adding the following Sentence:

(5.1) A registered code agency may issue a certificate for the occupancy of a building described in Sentence 1.3.3.4.(4) of Division C if the registered code agency,

(a) has been appointed to perform the functions described in clause 4.1 (4) (b) or (c) of the Act in respect of the construction of a building described in Sentence 1.3.3.4.(4) to which the certificate applies,

(b) has, in conformity with the Act, this Code and the quality management plan described in Clause 3.4.3.2.(1)(d), carried out the applicable functions for which the registered code agency was appointed, and

(c) is satisfied on reasonable grounds that, on the date on which the certificate for the occupancy of a building described in Sentence 1.3.3.4.(4) of Division C is issued, the construction of the building to which the certificate relates is in compliance with Clauses 1.3.3.4.(5)(a) to (j).

236. Clause 3.7.6.3.(2)(b) of Division C of the Regulation is amended by striking out “Sentences 3.7.4.2.(3) and (4)” at the end and substituting “Sentences 3.7.4.2.(3), (4) and (5)”.

237. Subclause 3.7.7.1.(1)(a)(i) of Division C of the Regulation is amended by striking out “subsection 14 (2) of the Act” at the end and substituting “section 14 of the Act”.

238. Article 4.1.1.1. of Division C of the Regulation is amended by adding the following Sentence:

(4) Despite the repeal of section 9 of the Act, the chief building official or a registered code agency continues to have the powers set out in that section, as it read immediately before subsection 2 (4) of Schedule 21 to the Good Government Act, 2009 comes into force, with respect to construction to which Sentence (1) applies, and they may exercise those powers subject to the conditions referred to in subsection 9 (3) of the Act.

239. Section 4.1. of Division C of the Regulation is amended by adding the following Subsection:

4.1.4. Transition, January 2012

4.1.4.1. Transition Rule

(1) Sentence 9.7.1.7.(1) and Subsection 9.25.3. of Division B and Sentence 1.3.5.1.(2) of Division C as they read on December 31, 2011 continue to apply with respect to construction for which a permit has been applied for before January 1, 2012.

240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.

(2) Subsections 222 (1) to (3) come into force on the day subsection 2 (2) of Schedule 21 to the Good Government Act, 2009 comes into force.

(3) Subsection 7 (8) and section 223 come into force on the day subsection 2 (3) of Schedule 21 to the Good Government Act, 2009 comes into force.

(4) Section 238 comes into force on the day subsection 2 (4) of Schedule 21 to the Good Government Act, 2009 comes into force.

(5) Sections 23, 26 and 31, subsection 32 (2), sections 36, 40, 45, 46 and 48 and subsection 214 (2) come into force on April 1, 2010.

(6) Section 114 comes into force on January 1, 2011.

(7) Subsection 7 (3) and sections 134, 180, 224 to 230, 235 and 239 come into force on January 1, 2012.